2. Position the article on the Printing Table. Substitute a piece of scrap paper for the actual
article if necessary.
3. For the correct imprinting pressure, always apply the pressure in two motions:
•
Bring handle down with light, easy motion, with arms and finger relaxed until the
type is almost touching the article to be imprinted.
•
Press down harder and hold for short (1 or 2 seconds) dwell.
•
Release the pressure, and gently bring the handle back to the starting position. Do not
let handle snap back.
4. Check the copy for errors in spelling.
5. If the position of the imprint is not satisfactory, release the Side Screw and adjust the Gauge
bar to re-position the article to be imprinted.
For Air-operated units:
•
Pressure is controlled by setting the pressure regulator on the compressor.
Clockwise
= increase pressure
Counter-clockwise
= reduce pressure
•
Dwell time is control by turning the Dwell Time dial on the front panel of the Pneumatic
Control Box.
Clockwise
= longer dwell time
Counter-clockwise
= shorter dwell time
Pressure Regulator
Dwell