background image

___________________________________________________________________________________________________________ 

REV 6/7/11 Page 5 of 14 

Skytech 3301P BE 

PROGRAM REVIEW 

  

 

 

 

 

 

 

 

 

If you want to review the settings for either the FACTORY program  
and/or your CUSTOMIZED program, you may do so by pressing the 
PROG button for one second.  To review other 
settings, press the PROG button allowing one  
second between each press of the PROG button.  If  
you press the PROG button for 4 seconds, then you  
go into the programming process.  Press the SET button  
should you hold the PROG button too long.   
 

PROGRAM CANCELLATION 

 
Should you want to cancel the CUSTOMIZED program that you have entered and return to the FACTORY program, you may do so.  To 
cancel a CUSTOMIZED program: 
 
1.  Press the SET button to make sure the LCD screen is in normal state. 
2.  Then press and hold the PROG button and, at the same time, press the SET button for a period of 10 seconds. 
3.  The customized programs will be cancelled when the display icons/numbers flash with some icons disappearing.  The LCD screen 

will begin flashing PROGRAM FOR, START AT, and the digits in the TIME and SET frames will begin flashing.  This confirms 
CUSTOMIZED programs have been cancelled. 

4.  Push the SET button to return LCD screen to normal state or wait 10 seconds and LCD screen will return to normal state 

automatically. 

 
 
 
 
 

  ADDITIONAL PROGRAMMING OPTIONS SWING TEMPERATURE DIFFERENTIAL 

 

The thermo-transmitter operates the fireplace system 
whenever the ROOM TEMPERATURE varies a certain number 
of degrees from the SET TEMPERATURE.  This variation is 
called the “SWING” or TEMPERATURE DIFFERENTIAL. The 
normal operating cycle of a fireplace system may be 2-4 times 
per hour depending on how well the room or home is insulated 
from the cold or drafts.  A smaller “swing number” increases 
the number of cycles so the room temperature is more 
constant.  A larger “swing number” decreases the number of 
cycles, which saves energy, in most cases.  The factory setting 
for the “swing number” is 2.  This represents a temperature 
variation of +/- 2 

0

 F

  (1 

0

C

) between SET temperature and 

ROOM temperature which determines when the fireplace will 
be activate.  The “SWING” number values are: 

1= +/- 1 

0

 F (.5 

0

C), 2= +/- 2 

0

 F  (1 

0

C), 3 = +/-3 

0

 F (1.6 

0

C).

 

 

To change the temperature “SWING” setting (1-3), press the 
AHEAD + BACK buttons simultaneously to display the current   
“SWING” 

setting in the SET TEMP frame.  The word SWING will display on 
the LCD screen. 

Press the UP or DOWN button to change the temperature 
differential or “SWING” (1-3).  See above for 1-3 “SWING” 
temperature values.  

To store the “swing number”, press the SET button or allow 15 
seconds to lapse, and the new “swing number” will be 
automatically programmed. 

 

MANUAL CHECK OF “SWING” OR TEMPERATURE DIFFERENTIAL 

 
The operation of the factory set “THERMO SWING” can be checked by adjusting the SET TEMP 2 

0

 F 

above or below the room 

temperature.  This will cause the system to turn ON or OFF.  Normally the system will only respond to temperature changes every two 
minutes.  Manually changing the SET temperature will activate the system in less than 10 seconds.  If the “SWING” is changed, then a 
new room temperature differential will respond.  Factory setting of SWING temperature is 2 

0

 F

.   

 

TIME

SET

AM

START

     AT

PROGRAM

        FOR

SU

MORN

1

UP

DOWN

MODE

TIMER
 TIME

SET

PROG

AHEAD

BACK

 

SWING

1

2

3

UP

DOWN

MODE

TIMER
 TIME

SET

PROG

AHEAD

BACK

 

f i r e - p a r t s . c o m

Summary of Contents for 3301P BE

Page 1: ...fifteen minutes for accurate temperature readings to appear LCD DISPLAY SCREEN 1 PROGRAM FOR Flashes when programming days of week and periods of the day When in normal state only current DAY displays...

Page 2: ...setting If no change is made to flashing digits within 15 seconds the system will complete the procedure last programmed and reset the display to its normal state INITIAL SET UP PROGRAMMING OF TRANSM...

Page 3: ...xt step The LCD screen will now display in its normal state PROGRAM OPERATION OF REMOTE CONTROL BUILT IN PROGRAM The transmitter has a factory program built in Each day has been broken into four perio...

Page 4: ...the PROG button in step 7 the next PERIOD of the same or next day will display on the LCD screen 9 To program the next PERIOD follow steps 3 4 5 6 and 7 10 Continue to follow steps 3 4 5 6 and 7 unti...

Page 5: ...SWING or TEMPERATURE DIFFERENTIAL The normal operating cycle of a fireplace system may be 2 4 times per hour depending on how well the room or home is insulated from the cold or drafts A smaller swin...

Page 6: ...o set the DESIRED room temperature press the MODE button to place the transmitter into THERMO mode THERMO ON or OFF will display 2 Then press the UP or DOWN button to select the DESIRED room temperatu...

Page 7: ...and OFF as the room temperature requires until the timer time has expired 4 To cancel the TIMER operation press the TIME RTIME button for more than 2 seconds OPERATIONAL NOTE When the TIMER is used in...

Page 8: ...s recommended that the thermopile voltage with the main burner OFF be no less than 450 millivolts for proper microprocessor performance IMPORTANT It is essential that proper voltage from the thermopil...

Page 9: ...nt of all wires The following wiring diagrams are for illustration purpose only Follow instructions from manufacturer of gas valve and or electronic module for correct wiring procedures Improper insta...

Page 10: ...cess of converting millivolts from the thermopile into DC volts required to operate the receiver This will continue for as long as the thermopile is in operation 4 Use the transmitter of the remote co...

Page 11: ...epted into the receiver The microprocessor that controls the security code matching procedure is controlled by a timing function If you are unsuccessful in matching the security code on the first atte...

Page 12: ...d to reset the receiver s operation BATTERY LIFE Life expectancy of alkaline batteries in the SKYTECH 3301P BE should be at least 12 months Replace all batteries annually When the Transmitter no longe...

Page 13: ...ON OFF depending on programmed SET temperature 4 PROGRAM indicates the system is operating with PROGRAMME settings OTHER OPERATIONS Press corresponding buttons on TRANSMITTER to activate functions TIM...

Page 14: ...ET TIME will begin to flash 6 Program SET TEMP by pressing UP or DOWN button 7 Again press PROG button The next PERIOD and DAY will begin to flash 8 Repeat steps 2 through 7 for all 7 DAYS until each...

Page 15: ...e workmanship or materials Damage to the SYSTEM caused by accident misuse abuse or installation error whether performed by a contractor Service Company or owner is not covered by this warranty Modific...

Page 16: ...nce into the receiver push the ON button on the transmitter and you are in business It s that easy The list price of 29 95 for the Santa s Helper has been cut almost in half to 15 00 USD for this excl...