MODE button on the transmitter.  A change in the beeping pattern, at the receiver indicates the transmitter’s code has been 
programmed into the receiver.   

5.  Make sure the transmitter is within the 15’-20’ range of the receiver. 
6.  Positioning of the receiver is important.  If the receiver is “enclosed” in a metal surround, the operation of the receiver may be 

affected as noted below.  Reposition the receiver to improve operating range. If the receiver is “enclosed” in a metal surround, this 
can:   

 

Cause the RF signal to get lost and not communicate with the receiver. 

 

Cause the working distance to be shorter than normal. 

NOTE:  A receiver located in an area, where the ambient temperature inside the case exceeds 160 

0

F, will cause THERMO-

SAFETY feature to cut in, requiring you to reposition the receiver to stop the warning beeps, and to “reset” the receiver’s operation. 

 

 

BATTERY LIFE 

 
Life expectancy of alkaline batteries in the SKYTECH 3301P BE should be at least 12 months.  Replace all batteries annually.  When 
the Transmitter no longer operates the receiver from a distance it did previously (i.e., the transmitter’s range has decreased) or the 
remote receiver does not function at all, the batteries should be checked in the transmitter. The Transmitter should operate with as little 
as 2.5 volts of battery power, measuring at the (2) 1.5-volt batteries.  

 

SPECIFICATIONS 
 

BATTERIES:  Transmitter 3V- 2 ea. AAA 1.5V, Alkaline                       
 

          Remote Receiver (NO BATTERIES)                         FCC ID No.’s: transmitter –(K9L3301TX); receiver – (K9L3301TX)  

Operating Frequency:  303.8MHZ                                         Canadian IC ID No.’s:  transmitter – 2439-3301TX; receiver – 2439-102-
760A 
 
 
 
 
 
 
 
 

 

 

 

FOR TECHNICAL  

U.S. INQUIRIES   

 

CANADIAN INQUIRIES 

 

 

 

 

SERVICE, CALL:  

888/672-8929 or   

 

877-472-3923  

 

 

 

 

 

 

 

260/459-1703 

 

 

 

 

 

 

 

 

 

 

Website:  skytechsystem.com 

 

MANUFACTURED EXCLUSIVELY FOR SKYTECH II, INC 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FCC REQUIREMENTS 

NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY 
UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S 
AUTHORITY TO OPERATE THE EQUIPMENT. 

 

f i r e - p a r t s . c o m

Summary of Contents for 3301P BE

Page 1: ...fifteen minutes for accurate temperature readings to appear LCD DISPLAY SCREEN 1 PROGRAM FOR Flashes when programming days of week and periods of the day When in normal state only current DAY displays...

Page 2: ...setting If no change is made to flashing digits within 15 seconds the system will complete the procedure last programmed and reset the display to its normal state INITIAL SET UP PROGRAMMING OF TRANSM...

Page 3: ...xt step The LCD screen will now display in its normal state PROGRAM OPERATION OF REMOTE CONTROL BUILT IN PROGRAM The transmitter has a factory program built in Each day has been broken into four perio...

Page 4: ...the PROG button in step 7 the next PERIOD of the same or next day will display on the LCD screen 9 To program the next PERIOD follow steps 3 4 5 6 and 7 10 Continue to follow steps 3 4 5 6 and 7 unti...

Page 5: ...SWING or TEMPERATURE DIFFERENTIAL The normal operating cycle of a fireplace system may be 2 4 times per hour depending on how well the room or home is insulated from the cold or drafts A smaller swin...

Page 6: ...o set the DESIRED room temperature press the MODE button to place the transmitter into THERMO mode THERMO ON or OFF will display 2 Then press the UP or DOWN button to select the DESIRED room temperatu...

Page 7: ...and OFF as the room temperature requires until the timer time has expired 4 To cancel the TIMER operation press the TIME RTIME button for more than 2 seconds OPERATIONAL NOTE When the TIMER is used in...

Page 8: ...s recommended that the thermopile voltage with the main burner OFF be no less than 450 millivolts for proper microprocessor performance IMPORTANT It is essential that proper voltage from the thermopil...

Page 9: ...nt of all wires The following wiring diagrams are for illustration purpose only Follow instructions from manufacturer of gas valve and or electronic module for correct wiring procedures Improper insta...

Page 10: ...cess of converting millivolts from the thermopile into DC volts required to operate the receiver This will continue for as long as the thermopile is in operation 4 Use the transmitter of the remote co...

Page 11: ...epted into the receiver The microprocessor that controls the security code matching procedure is controlled by a timing function If you are unsuccessful in matching the security code on the first atte...

Page 12: ...d to reset the receiver s operation BATTERY LIFE Life expectancy of alkaline batteries in the SKYTECH 3301P BE should be at least 12 months Replace all batteries annually When the Transmitter no longe...

Page 13: ...ON OFF depending on programmed SET temperature 4 PROGRAM indicates the system is operating with PROGRAMME settings OTHER OPERATIONS Press corresponding buttons on TRANSMITTER to activate functions TIM...

Page 14: ...ET TIME will begin to flash 6 Program SET TEMP by pressing UP or DOWN button 7 Again press PROG button The next PERIOD and DAY will begin to flash 8 Repeat steps 2 through 7 for all 7 DAYS until each...

Page 15: ...e workmanship or materials Damage to the SYSTEM caused by accident misuse abuse or installation error whether performed by a contractor Service Company or owner is not covered by this warranty Modific...