OPERATING PROGRAM

8.  Program Stop

9.  Program Complete

During the charging process, press STOP to stop the charging process.

When the charging process finishes, an audible sound will be heard.

Charging Program

Depends on different battery type, the operation programs are different.

NiMH
NiCd

RE-PEAK

CYCLE

Pb

Batt
Type

Operation
Program

Description

This charging mode is for charging LiPo/LiFe/LiIon/LiHV battery in normal mode.

This program is for charging or discharging LiPo/LiFe/LiIon/LiHV
battery which will not be used for long time.

The charging capacity may be a bit smaller than normal charging but 
the process time will be reduced.

This mode is for balancing the voltage of LiPo/LiFe/LiIon/LiHV battery
cells while charging.

The charger will charge NiMH and NiCd batteries using the charge 
current set by the user.

In this program the charger detects the condition of the battery which 
is connected to the output and automatically charges the battery.

Note: you should set up the upper limit of the charge current to 
avoid damage by excessive feeding current. Some batteries of 
low resistance and capacity can lead to higher current.

In re-peak charge mode, the charger can peak charge the battery 
once, twice or three times in a row automatically. This is good for 
confirming the battery is fully charged, and for checking how well the 
battery receives fast charges. 

1 to 5 cyclic and continuous process of charge>discharge or 
discharge>charge is operable for battery refreshing and balancing to 
stimulate the battery's activity.

LiPo
Lilon
LiFe
LiHV

CHARGE

STORAGE

FAST CHG

BAL CHARGE

CHARGE

AUTO CHG

DISCHARGE

CHARGE

DISCHARGE

This mode is for discharging NiMH/NiCd battery.

This mode is for charging Pb battery.

This mode is for discharging Pb battery.

MICRO CHARGE

MICRO STORAGE

This mode is for balancing the voltage of LiPo/LiFe/LiIon/LiHV battery
cells while charging with balance port.

This program is for charging or discharging LiPo/LiFe/LiIon/LiHV which
will not be used for long time with balance port.

DISCHARGE

This mode is for discharging LiPo/LiFe/LiIon/LiHV battery. 

Summary of Contents for Ultimate Duo 1400W / 30A

Page 1: ...SkyRC Technology Co Ltd 2015 BALANCE CHARGER BALANCE CHARGER BALANCE CHARGER DISCHARGER DISCHARGER DISCHARGER INSTRUCTION MANUAL...

Page 2: ...PROGRAM BATTERY MEMORY SET AND CALL OUT SYSTEM SETTING BATTERY METER BATTERY RESISTANCE METER WARNING AND ERROR MESSAGE USING THE CHARGE CONTROL SOFTWARE CHARGE MASTER SPECIFICATION CONFORMITY DECLAR...

Page 3: ...annel one What s more users could also use it as Lithium Battery Meter and Lithium Battery Internal Resistance Meter There are Automatic Charging Current Limit Capacity Limit Temperature Threshold and...

Page 4: ...Easy Reading Batt Prog Stop Button DEC INC Button Start Enter Button Batt Prog Stop Button DEC INC Button Start Enter Button DC Input 11 30V Output 1 Output 2 USB Port for PC Control Firmware Upgrade...

Page 5: ...Master The free Charge Master software gives you unparalleled ability to operate the charger through the computer You can monitor pack voltage cell voltage and other data during the charging view cha...

Page 6: ...g mode Capacity Limit The charging capacity is always calculated as the charging current multiplied by time If the charging capacity exceeds the limit the process will be terminated automatically when...

Page 7: ...e specifications of the battery to be charged or discharged to ensure it meets the requirements of this charger If the program is set up incorrectly the battery and charger may be damaged It can cause...

Page 8: ...cts at any point in the circuit Charging During charge process a specific quantity of electrical energy is fed into the battery The charge quantity is calculated by multiplying charge current by charg...

Page 9: ...If they are partly used and recharged before the whole charge is accomplished they remember this and will only use that part of their capacity next time This is a memory effect It is said that NiCd a...

Page 10: ...NiMH CHARGE CURRENT 2 0A DEC INC NiMH DISCHARGE 0 1A CUT 1 0V NiMH CYCLE CHG DCHG 1 DEC INC PROGRAM SELECT LiPo BATT LiPo BALANCE 2 0A 7 4V 2S LiPo CHARGE 2 0A 7 4V 2S LiPo FASTCHG 2 0A 7 4V 2S LiPo...

Page 11: ...screen press the BATT PROG STOP button once When you power on the charger it will enter LiPo Battery balance program directly You could change the mode balance mode normal charge mode fast charge mode...

Page 12: ...the START ENTER button to make the current value blink then change the value by pressing DEC and INC button The value will be stored by re pressing the START ENTER button At the same time cut voltage...

Page 13: ...ecting the battery Important Before connecting a battery it is absolutely essential to check one last time that you have set the parameters correctly If the settings are incorrect the battery may be d...

Page 14: ...the programs and press START ENTER to enter LiPo BATT Program 5 Battery Setting LiPo BALANCE CHG 2 0A 11 1V 3S Press INC and DEC to go through all the modes and press START ENTER to enter LiPo Balance...

Page 15: ...en LP4s 1 5A 12 14V BAL 000 50 00022 4 07 4 06 4 11 V 0 00 0 00 0 00 V Fuel 90 Cell 4 10V INC INC LP4s 1 5A 12 14V BAL 000 50 00022 Ext Temp Int Temp 37 C DEC Temp Cut Off 50 C DEC Final voltage when...

Page 16: ...ically charges the battery Note you should set up the upper limit of the charge current to avoid damage by excessive feeding current Some batteries of low resistance and capacity can lead to higher cu...

Page 17: ...1 Battery Memory Set START ENTER DEC INC DEC INC BATTERY MEMORY SET AND CALL OUT Synchronous Mode Function When charging two same batteries both charging channels can be set by channel one ON OFF Pro...

Page 18: ...ile Press the START ENTER for 3 seconds to call out the memory 2 Battery Memory Call Out Load the memory set Press START ENTER for 3 seconds to start the process START ENTER 3 Seconds CHARGE CURRENT 4...

Page 19: ...ll charge of the battery OFF ON 100 50000 mAh It is essential for users to do system settings before use After entering system setting program the screen displays the following information in sequence...

Page 20: ...1 00 FW 1 10 Press ENTER to load factory default setting It indicates the hardware and firmware version Synchron Enable OFF Max Power Set 700W Power Source DC Power Supply DC Power Supply Battery Choo...

Page 21: ...lance wires to balance board BATT PROGRAM BATT METER 4 20 4 19 4 19 V 4 18 4 18 4 19 V Press the START ENTER to enter the Lithium Battery Meter program The screen indicate each cell s voltage START EN...

Page 22: ...t and balance wires to balance socket This diagram shows the correct way to connect your battery to check the resistance Press the START ENTER to enter the Lithium Battery Resistance program The scree...

Page 23: ...unit goes too high INT TEMP TOO HI DC IN TOO LOW Input voltage less than 11V Input voltage higher than 30V DC IN TOO HIGH BATTERY WAS FULL The battery voltage is higher than the maximum voltage which...

Page 24: ...to using Charger Master software The Charger Master software can support one channel only In order to connect the charger to the computer and use the Charge Master you are required to use a USB cable...

Page 25: ...00015 eFUEL 15 30V 50A Power Supply RECOMMENDED PRODUCTS SK 600071 Dual Port Safe Parallel Adapter Cell Count 2 8S Balance Connector Type XH Fuse Protect Over Current Indicator SPECIFICATION 23 Ultima...

Page 26: ...x 800mA cell Trickle Current for NiMH NiCad 50 300mA OFF Reading Voltage Range 0 1 34 8V cell Battery Types Cells LiPo LiIon LiFe LiHV 1 8cells NiCad 1 20cells Pb 2 24V NiMH Battery Capacity Range NiC...

Page 27: ...te Duo 1400W SKYRC Ultimate Duo 1400W satisfy all relevant and mandatory CE directives and FCC Part 15 Subpart B 2014 For EC directives The product has been tested to meet the following technical stan...

Page 28: ...circuit power chart 4 2 8 4 12 6 16 8 21 0 25 2 29 4 33 6 4 1 8 2 12 3 16 4 20 5 24 6 28 7 32 8 3 6 7 2 10 8 14 4 18 0 21 6 25 2 28 8 4 35 8 7 13 05 17 4 21 75 26 1 30 45 34 8 3 7 7 4 11 1 14 8 18 5 2...

Page 29: ...18 0 20 0 22 0 24 0 3 0 4 5 6 0 7 5 9 0 10 5 12 0 13 5 15 0 16 5 18 0 19 5 21 0 22 5 24 0 25 5 27 0 28 5 30 0 7 35 9 80 12 25 14 70 17 15 19 60 22 05 24 50 26 95 29 40 30 0 30 0 30 0 30 0 30 0 30 0 3...

Page 30: ...8 A C rating Capacity is also referred to as the C rating Some battery suppliers recommend charge and discharge currents based on the battery C rating A battery s 1C current is the same number as the...

Page 31: ...occurred Liability exclusion 29 Ultimate Duo 1400W Warranty and service We guarantee this product to be free of manufacturing and assembly defects for a period of one year from the time of purchase Th...

Page 32: ...Printed in China 2015 04 All specifications and figures are subject to change without notice Manufactured by SKYRC TECHNOLOGY CO LTD www skyrc com 7504 0 01 602...

Reviews: