Skyrc Ultimate Duo 1400W / 30A Instruction Manual Download Page 10

PROGRAM FLOW CHART  

·

 

08

Ultimate Duo 1400W

DEC

INC

LiPo MICRO STORE
500mA     7.4V (2S)

PROGRAM SELECT
      BATT MEMORY

ENTER

START

BATT MEMORY [1]
ENTER SET

ENTER

START

BATT TYPE
LiPo

DEC

INC

BATT VOLTS
       7.4V ( 2S )

DEC

INC

CHARGE CURRENT
                           4.9A

DEC

INC

DSCH CURRENT
                           2.2A

DSCH VOLTAGE
                 3.0V/CELL

TVC=YOUR RISK
                         4.20V

DEC

INC

ENTER

START

ENTER

START

PROGRAM SELECT
    SYSTEM SET->

Rest Time
CHG>DCHG    10Min

ENTER

START

DEC INC

SAFETY TIMER
ON                  120Min

DEC

INC

Capacity Cut-Off
ON             5000mAH

DEC

INC

Key Beep             ON
Buzzer                 ON

DEC

INC

Power Source?
DC Power Supply

Ext. Temp              0C
Int. Temp              37C

DEC

INC

LOAD FACTORY SET
                       ENTER

VERSION
                            1.00

Stop

Batt Type

DEC

INC

SAVE PROGRAM 
                      ENTER

DEC

INC

SAVE PROGRAM 
SAVE….

BATT MEMORY [1]
LiPo  7.4V (2S )

ENTER

START

BATT MEMORY [1]
C:4.9A  D:2.2A

ENTER CHARGER
LOAD……

LiPo BALANCE
4.9A      7.4V(2S)

LiPo CHARGE
4.9A      7.4V(2S)

DEC

INC

LiPo FAST CHG
4.9A      7.4V(2S)

DEC

INC

LiPo STORAGE 
4.9A      7.4V(2S)

LiPo DISCHARGE
2.2A      7.4V(2S)

DEC

INC

DEC

INC

BATT MEMORY 2
NiMH   2.4V (2S)

BATT TYPE
MiMH

DEC

INC

BATT VOLTS

2.4V (2S)

ENTER

START

CHARGE CURRENT
                          3.3A

DEC

INC

DEC

INC

TRICKLE
              100mA

DEC

INC

PEAK DELAY
                         1Min

DEC

INC

DSCH CURRENT
                          2.2A

DEC

INC

DSCH VOLTAGE

1.1V/CELL

DEC

INC

DELTA PEAK SENSE

4Mv/C

SAVE PROGRAM 
ENTER

DEC

INC

BATT MEMORY 3
Pb   4V (2S)

ENTER

START

BATT TYPE
Pb

BATT VOLTS
                   4.0V (2S)

DEC

INC

CHARGE CURRENT
                          3.3A

DEC

INC

DSCH CURRENT

1.5A

DEC

INC

DSCH VOLTAGE

1.7V/CELL

DEC

INC

DEC

INC

SAVE PROGRAM 
ENTER

DEC

INC

PROGRAM SELECT
            Pb BATT 

ENTER

START

Pb CHARGE
2.0A     2.0V (1P)

DEC

INC

Pb DISCHARGE
0.1A     2.0V (1P)

DEC

INC

PROGRAM SELECT
          NiCD BATT

NiCD CHARGE
CURRENT     2.0A

ENTER

START

DEC

INC

NiCD DISCHARGE
0.1A       CUT: 1.0V

DEC

INC

NiCD CYCLE
CHG>DCHG     

  1

DEC

INC

PROGRAM SELECT
          NiMH BATT 

ENTER

START

NiMH CHARGE
CURRENT     2.0A

DEC

INC

NiMH DISCHARGE
0.1A       CUT: 1.0V

NiMH CYCLE
CHG>DCHG          1

DEC

INC

PROGRAM SELECT
           LiPo BATT

LiPo BALANCE
2.0A     7.4V (2S)

LiPo CHARGE
2.0A         7.4V (2S)

LiPo FAST CHG
2.0A     7.4V (2S)

LiPo STORAGE
2.0A     7.4V (2S)

LiPo DISCHARGE
2.0A         7.4V (2S)

ENTER

START

DEC

INC

DEC

INC

DEC

INC

DEC

INC

DEC

INC

DEC

INC

PROGRAM SELECT
           Lilo BATT

Lilo BALANCE
2.0A     7.2V (2S)

Lilo CHARGE
2.0A     7.2V (2S)

Lilo FAST CHG
2.0A    7.2V (2S)

Lilo STORAGE
2.0A    7.2V (2S)

Lilo DISCHARGE
2.0A     7.2V (2S)

ENTER

START

DEC

INC

DEC

INC

DEC

INC

DEC

INC

PROGRAM SELECT
           LiFe BATT

LiFe BALANCE
2.0A     6.6V (2S)

LiFe CHARGE
2.0A     6.6V (2S)

LiFe FAST CHG
2.0A    6.6V (2S)

LiFe STORAGE
2.0A    6.6V (2S)

LiFe DISCHARGE
2.0A     6.6V (2S)

ENTER

START

DEC

INC

DEC

INC

DEC

INC

DEC

INC

DEC

INC

ENTER

START

PROGRAM SELECT

      BATT METER

4.20   4.19    4.19 V
0.00   0.00    0.00 V

DEC

INC

DEC

INC

DEC

INC

DEC

INC

DEC

INC

DEC

INC

NiCD RE-PEAK
                         1

DEC

INC

NiMH RE-PEAK
                         1

DEC

INC

NiMH Auto CHARGE
CURRENT     2.0A

DEC

INC

NiCD Auto CHARGE
CURRENT     2.0A

DEC

INC

TEMPERATURE
CUT-OFF          50C

DEC

INC

TEMPERATURE
CUT-OFF          50C

DEC

INC

DEC

INC

TEMPERATURE
CUT-OFF          50C

LiPo MICRO CHG
500mA     7.4V (2S)

DEC

INC

LiIo MICRO CHG
500mA     7.4V (2S)

DEC

INC

LiFe MICRO CHG
500mA     7.4V (2S)

DEC

INC

LiPo MICRO STORE
500mA     7.4V (2S)

DEC

INC

LiIo MICRO STORE
500mA     7.4V (2S)

DEC

INC

LiFe MICRO STORE
500mA     7.4V (2S)

DEC

INC

Synchron Enable?
                           OFF 

DEC

INC

PROGRAM SELECT
           LiHV BATT

LiHV BALANCE
2.0A     7.6V (2S)

LiHV CHARGE
2.0A     7.6V (2S)

LiHV FAST CHG
2.0A    7.6V (2S)

LiHV STORAGE
2.0A    7.6V (2S)

LiHV DISCHARGE
2.0A     7.6V (2S)

ENTER

START

DEC

INC

DEC

INC

DEC

INC

DEC

INC

DEC

INC

LiHV MICRO CHG
500mA     7.4V (2S)

DEC

INC

LiHV MICRO STORE
500mA     7.4V (2S)

DEC

INC

DEC

INC

ENTER

START

BATT/PROGRAM
BATT RESISTANCE

1:    5m

Ω

2

:

3m

Ω

3:    4m

Ω

4

:

3m

Ω

DEC

INC

DEC

INC

START

/

ENTER

>

3s

DEC

INC

LiPo MICRO CHG
500mA     7.4V (2S)

5:    4m

Ω

6

:

3m

Ω

MAIN 0.00V  
H0.000V     L0.000V

DEC

INC

0.00 V  0.00 V

Max Power Set
                         700W

DEC

INC

DEC

INC

DEC

INC

Summary of Contents for Ultimate Duo 1400W / 30A

Page 1: ...SkyRC Technology Co Ltd 2015 BALANCE CHARGER BALANCE CHARGER BALANCE CHARGER DISCHARGER DISCHARGER DISCHARGER INSTRUCTION MANUAL...

Page 2: ...PROGRAM BATTERY MEMORY SET AND CALL OUT SYSTEM SETTING BATTERY METER BATTERY RESISTANCE METER WARNING AND ERROR MESSAGE USING THE CHARGE CONTROL SOFTWARE CHARGE MASTER SPECIFICATION CONFORMITY DECLAR...

Page 3: ...annel one What s more users could also use it as Lithium Battery Meter and Lithium Battery Internal Resistance Meter There are Automatic Charging Current Limit Capacity Limit Temperature Threshold and...

Page 4: ...Easy Reading Batt Prog Stop Button DEC INC Button Start Enter Button Batt Prog Stop Button DEC INC Button Start Enter Button DC Input 11 30V Output 1 Output 2 USB Port for PC Control Firmware Upgrade...

Page 5: ...Master The free Charge Master software gives you unparalleled ability to operate the charger through the computer You can monitor pack voltage cell voltage and other data during the charging view cha...

Page 6: ...g mode Capacity Limit The charging capacity is always calculated as the charging current multiplied by time If the charging capacity exceeds the limit the process will be terminated automatically when...

Page 7: ...e specifications of the battery to be charged or discharged to ensure it meets the requirements of this charger If the program is set up incorrectly the battery and charger may be damaged It can cause...

Page 8: ...cts at any point in the circuit Charging During charge process a specific quantity of electrical energy is fed into the battery The charge quantity is calculated by multiplying charge current by charg...

Page 9: ...If they are partly used and recharged before the whole charge is accomplished they remember this and will only use that part of their capacity next time This is a memory effect It is said that NiCd a...

Page 10: ...NiMH CHARGE CURRENT 2 0A DEC INC NiMH DISCHARGE 0 1A CUT 1 0V NiMH CYCLE CHG DCHG 1 DEC INC PROGRAM SELECT LiPo BATT LiPo BALANCE 2 0A 7 4V 2S LiPo CHARGE 2 0A 7 4V 2S LiPo FASTCHG 2 0A 7 4V 2S LiPo...

Page 11: ...screen press the BATT PROG STOP button once When you power on the charger it will enter LiPo Battery balance program directly You could change the mode balance mode normal charge mode fast charge mode...

Page 12: ...the START ENTER button to make the current value blink then change the value by pressing DEC and INC button The value will be stored by re pressing the START ENTER button At the same time cut voltage...

Page 13: ...ecting the battery Important Before connecting a battery it is absolutely essential to check one last time that you have set the parameters correctly If the settings are incorrect the battery may be d...

Page 14: ...the programs and press START ENTER to enter LiPo BATT Program 5 Battery Setting LiPo BALANCE CHG 2 0A 11 1V 3S Press INC and DEC to go through all the modes and press START ENTER to enter LiPo Balance...

Page 15: ...en LP4s 1 5A 12 14V BAL 000 50 00022 4 07 4 06 4 11 V 0 00 0 00 0 00 V Fuel 90 Cell 4 10V INC INC LP4s 1 5A 12 14V BAL 000 50 00022 Ext Temp Int Temp 37 C DEC Temp Cut Off 50 C DEC Final voltage when...

Page 16: ...ically charges the battery Note you should set up the upper limit of the charge current to avoid damage by excessive feeding current Some batteries of low resistance and capacity can lead to higher cu...

Page 17: ...1 Battery Memory Set START ENTER DEC INC DEC INC BATTERY MEMORY SET AND CALL OUT Synchronous Mode Function When charging two same batteries both charging channels can be set by channel one ON OFF Pro...

Page 18: ...ile Press the START ENTER for 3 seconds to call out the memory 2 Battery Memory Call Out Load the memory set Press START ENTER for 3 seconds to start the process START ENTER 3 Seconds CHARGE CURRENT 4...

Page 19: ...ll charge of the battery OFF ON 100 50000 mAh It is essential for users to do system settings before use After entering system setting program the screen displays the following information in sequence...

Page 20: ...1 00 FW 1 10 Press ENTER to load factory default setting It indicates the hardware and firmware version Synchron Enable OFF Max Power Set 700W Power Source DC Power Supply DC Power Supply Battery Choo...

Page 21: ...lance wires to balance board BATT PROGRAM BATT METER 4 20 4 19 4 19 V 4 18 4 18 4 19 V Press the START ENTER to enter the Lithium Battery Meter program The screen indicate each cell s voltage START EN...

Page 22: ...t and balance wires to balance socket This diagram shows the correct way to connect your battery to check the resistance Press the START ENTER to enter the Lithium Battery Resistance program The scree...

Page 23: ...unit goes too high INT TEMP TOO HI DC IN TOO LOW Input voltage less than 11V Input voltage higher than 30V DC IN TOO HIGH BATTERY WAS FULL The battery voltage is higher than the maximum voltage which...

Page 24: ...to using Charger Master software The Charger Master software can support one channel only In order to connect the charger to the computer and use the Charge Master you are required to use a USB cable...

Page 25: ...00015 eFUEL 15 30V 50A Power Supply RECOMMENDED PRODUCTS SK 600071 Dual Port Safe Parallel Adapter Cell Count 2 8S Balance Connector Type XH Fuse Protect Over Current Indicator SPECIFICATION 23 Ultima...

Page 26: ...x 800mA cell Trickle Current for NiMH NiCad 50 300mA OFF Reading Voltage Range 0 1 34 8V cell Battery Types Cells LiPo LiIon LiFe LiHV 1 8cells NiCad 1 20cells Pb 2 24V NiMH Battery Capacity Range NiC...

Page 27: ...te Duo 1400W SKYRC Ultimate Duo 1400W satisfy all relevant and mandatory CE directives and FCC Part 15 Subpart B 2014 For EC directives The product has been tested to meet the following technical stan...

Page 28: ...circuit power chart 4 2 8 4 12 6 16 8 21 0 25 2 29 4 33 6 4 1 8 2 12 3 16 4 20 5 24 6 28 7 32 8 3 6 7 2 10 8 14 4 18 0 21 6 25 2 28 8 4 35 8 7 13 05 17 4 21 75 26 1 30 45 34 8 3 7 7 4 11 1 14 8 18 5 2...

Page 29: ...18 0 20 0 22 0 24 0 3 0 4 5 6 0 7 5 9 0 10 5 12 0 13 5 15 0 16 5 18 0 19 5 21 0 22 5 24 0 25 5 27 0 28 5 30 0 7 35 9 80 12 25 14 70 17 15 19 60 22 05 24 50 26 95 29 40 30 0 30 0 30 0 30 0 30 0 30 0 3...

Page 30: ...8 A C rating Capacity is also referred to as the C rating Some battery suppliers recommend charge and discharge currents based on the battery C rating A battery s 1C current is the same number as the...

Page 31: ...occurred Liability exclusion 29 Ultimate Duo 1400W Warranty and service We guarantee this product to be free of manufacturing and assembly defects for a period of one year from the time of purchase Th...

Page 32: ...Printed in China 2015 04 All specifications and figures are subject to change without notice Manufactured by SKYRC TECHNOLOGY CO LTD www skyrc com 7504 0 01 602...

Reviews: