Skyrc Ultimate Duo 1400W / 30A Instruction Manual Download Page 14

·

 

12

Ultimate Duo 1400W

OPERATING PROGRAM

Locate the flowcharts show the entire programming menu. It is highly recommended to 
have these flowcharts handy while learning to operate this charger.
There are two main ways in which to set the charger.

A memory profile is available for setting and storing pertinent information for up to 
10 different batteries. Once a battery's information is stored into a memory it will be 
retained  until  changed  again  manually.  Recalling  a  battery's  memory  number 
makes the charger instantly ready to go! 
If  you  do  not  wish  to  use  the  battery  memories,  this  charger  can  be  manually  set 
before each use.

2. Getting started

(1)

(2)

For following step, all are basing on manually set

3.  BATT/PROGRAM Select

B A T T / P R O G R A M
         L i P o B A T T

4.  Mode Select

6.  Program Start

L i P o B A L A N C E C H G
2 . 0 A   1 1 . 1 V ( 3 S )

Press  INC  and  DEC  to  go  through  all  the  programs  and  press 
START/ENTER to enter LiPo BATT Program.

5.  Battery Setting

L i P o B A L A N C E C H G
2 . 0 A   1 1 . 1 V ( 3 S )

Press  INC  and  DEC  to  go  through  all  the  modes  and  press 
START/ENTER to enter LiPo Balance Charge Mode.

Press START/ENTER, the current value will start to blink, press 
INC and DEC to change the value and press START/ENTER to 
confirm your setting.
At  the  same  time,  the  battery  cells  number  will  start  to  blink, 
press  INC  and    DEC  to  change  the  value  and  press 
START/ENTER to confirm your setting.

L i P o B A L A N C E C H G
2 . 0 A   1 1 . 1 V ( 3 S )

B A T T E R Y C H E C K 
W A I T . . .

L i P o B A L A N C E C H G
2 . 0 A   1 1 . 1 V ( 3 S )

Press  and  hold  START/ENTER  for  3  seconds  to  start  the 
program.

The charger is detecting the battery cell. 

R  shows  the  number  of  cells  detected  by  the  charger  and  S  is 
the  number  of  cells  set  by  you  at  the  previous  screen.  If  both 
numbers  are  not  identical,  press  STOP  to  go  back  to  previous 
screen to recheck the number of cells of the battery pack before 
going ahead.

R : 3 S E R  S : 3 S E R
C A N C E L ( S T O P )

START/ENTER

START/ENTER

START/ENTER

START/ENTER

START/ENTER
> 3 Seconds

Summary of Contents for Ultimate Duo 1400W / 30A

Page 1: ...SkyRC Technology Co Ltd 2015 BALANCE CHARGER BALANCE CHARGER BALANCE CHARGER DISCHARGER DISCHARGER DISCHARGER INSTRUCTION MANUAL...

Page 2: ...PROGRAM BATTERY MEMORY SET AND CALL OUT SYSTEM SETTING BATTERY METER BATTERY RESISTANCE METER WARNING AND ERROR MESSAGE USING THE CHARGE CONTROL SOFTWARE CHARGE MASTER SPECIFICATION CONFORMITY DECLAR...

Page 3: ...annel one What s more users could also use it as Lithium Battery Meter and Lithium Battery Internal Resistance Meter There are Automatic Charging Current Limit Capacity Limit Temperature Threshold and...

Page 4: ...Easy Reading Batt Prog Stop Button DEC INC Button Start Enter Button Batt Prog Stop Button DEC INC Button Start Enter Button DC Input 11 30V Output 1 Output 2 USB Port for PC Control Firmware Upgrade...

Page 5: ...Master The free Charge Master software gives you unparalleled ability to operate the charger through the computer You can monitor pack voltage cell voltage and other data during the charging view cha...

Page 6: ...g mode Capacity Limit The charging capacity is always calculated as the charging current multiplied by time If the charging capacity exceeds the limit the process will be terminated automatically when...

Page 7: ...e specifications of the battery to be charged or discharged to ensure it meets the requirements of this charger If the program is set up incorrectly the battery and charger may be damaged It can cause...

Page 8: ...cts at any point in the circuit Charging During charge process a specific quantity of electrical energy is fed into the battery The charge quantity is calculated by multiplying charge current by charg...

Page 9: ...If they are partly used and recharged before the whole charge is accomplished they remember this and will only use that part of their capacity next time This is a memory effect It is said that NiCd a...

Page 10: ...NiMH CHARGE CURRENT 2 0A DEC INC NiMH DISCHARGE 0 1A CUT 1 0V NiMH CYCLE CHG DCHG 1 DEC INC PROGRAM SELECT LiPo BATT LiPo BALANCE 2 0A 7 4V 2S LiPo CHARGE 2 0A 7 4V 2S LiPo FASTCHG 2 0A 7 4V 2S LiPo...

Page 11: ...screen press the BATT PROG STOP button once When you power on the charger it will enter LiPo Battery balance program directly You could change the mode balance mode normal charge mode fast charge mode...

Page 12: ...the START ENTER button to make the current value blink then change the value by pressing DEC and INC button The value will be stored by re pressing the START ENTER button At the same time cut voltage...

Page 13: ...ecting the battery Important Before connecting a battery it is absolutely essential to check one last time that you have set the parameters correctly If the settings are incorrect the battery may be d...

Page 14: ...the programs and press START ENTER to enter LiPo BATT Program 5 Battery Setting LiPo BALANCE CHG 2 0A 11 1V 3S Press INC and DEC to go through all the modes and press START ENTER to enter LiPo Balance...

Page 15: ...en LP4s 1 5A 12 14V BAL 000 50 00022 4 07 4 06 4 11 V 0 00 0 00 0 00 V Fuel 90 Cell 4 10V INC INC LP4s 1 5A 12 14V BAL 000 50 00022 Ext Temp Int Temp 37 C DEC Temp Cut Off 50 C DEC Final voltage when...

Page 16: ...ically charges the battery Note you should set up the upper limit of the charge current to avoid damage by excessive feeding current Some batteries of low resistance and capacity can lead to higher cu...

Page 17: ...1 Battery Memory Set START ENTER DEC INC DEC INC BATTERY MEMORY SET AND CALL OUT Synchronous Mode Function When charging two same batteries both charging channels can be set by channel one ON OFF Pro...

Page 18: ...ile Press the START ENTER for 3 seconds to call out the memory 2 Battery Memory Call Out Load the memory set Press START ENTER for 3 seconds to start the process START ENTER 3 Seconds CHARGE CURRENT 4...

Page 19: ...ll charge of the battery OFF ON 100 50000 mAh It is essential for users to do system settings before use After entering system setting program the screen displays the following information in sequence...

Page 20: ...1 00 FW 1 10 Press ENTER to load factory default setting It indicates the hardware and firmware version Synchron Enable OFF Max Power Set 700W Power Source DC Power Supply DC Power Supply Battery Choo...

Page 21: ...lance wires to balance board BATT PROGRAM BATT METER 4 20 4 19 4 19 V 4 18 4 18 4 19 V Press the START ENTER to enter the Lithium Battery Meter program The screen indicate each cell s voltage START EN...

Page 22: ...t and balance wires to balance socket This diagram shows the correct way to connect your battery to check the resistance Press the START ENTER to enter the Lithium Battery Resistance program The scree...

Page 23: ...unit goes too high INT TEMP TOO HI DC IN TOO LOW Input voltage less than 11V Input voltage higher than 30V DC IN TOO HIGH BATTERY WAS FULL The battery voltage is higher than the maximum voltage which...

Page 24: ...to using Charger Master software The Charger Master software can support one channel only In order to connect the charger to the computer and use the Charge Master you are required to use a USB cable...

Page 25: ...00015 eFUEL 15 30V 50A Power Supply RECOMMENDED PRODUCTS SK 600071 Dual Port Safe Parallel Adapter Cell Count 2 8S Balance Connector Type XH Fuse Protect Over Current Indicator SPECIFICATION 23 Ultima...

Page 26: ...x 800mA cell Trickle Current for NiMH NiCad 50 300mA OFF Reading Voltage Range 0 1 34 8V cell Battery Types Cells LiPo LiIon LiFe LiHV 1 8cells NiCad 1 20cells Pb 2 24V NiMH Battery Capacity Range NiC...

Page 27: ...te Duo 1400W SKYRC Ultimate Duo 1400W satisfy all relevant and mandatory CE directives and FCC Part 15 Subpart B 2014 For EC directives The product has been tested to meet the following technical stan...

Page 28: ...circuit power chart 4 2 8 4 12 6 16 8 21 0 25 2 29 4 33 6 4 1 8 2 12 3 16 4 20 5 24 6 28 7 32 8 3 6 7 2 10 8 14 4 18 0 21 6 25 2 28 8 4 35 8 7 13 05 17 4 21 75 26 1 30 45 34 8 3 7 7 4 11 1 14 8 18 5 2...

Page 29: ...18 0 20 0 22 0 24 0 3 0 4 5 6 0 7 5 9 0 10 5 12 0 13 5 15 0 16 5 18 0 19 5 21 0 22 5 24 0 25 5 27 0 28 5 30 0 7 35 9 80 12 25 14 70 17 15 19 60 22 05 24 50 26 95 29 40 30 0 30 0 30 0 30 0 30 0 30 0 3...

Page 30: ...8 A C rating Capacity is also referred to as the C rating Some battery suppliers recommend charge and discharge currents based on the battery C rating A battery s 1C current is the same number as the...

Page 31: ...occurred Liability exclusion 29 Ultimate Duo 1400W Warranty and service We guarantee this product to be free of manufacturing and assembly defects for a period of one year from the time of purchase Th...

Page 32: ...Printed in China 2015 04 All specifications and figures are subject to change without notice Manufactured by SKYRC TECHNOLOGY CO LTD www skyrc com 7504 0 01 602...

Reviews: