background image

SK-600125-01

G 1 2 2 0

Press            button to enter into G1220* 

interface, then connect G1220 charging hub 

to PC1260 charger.

* G1220 is an optional part, which is not 

included in the package.

G1220 CHARGING HUB

-

5

-

-

6

-

SYSTEM SETUP

Press          few times until the screen displays the system setup.

Key Tone
(ON/OFF)

ERRORS

Message

Analysis

BATTERY VOLTAGE METER

Press           few times until the screen displays the battery meter. This function can detect the remaining
capacity, battery voltage per cell, total voltage, highest voltage & lowest voltage

3

.

9 7

3

.

9 9

3

.

9 5 V

3

.

9 9

3

.

9 9

3

.

9 7 V

total

voltage

BATTERY RESISTANCE METER

Press         few times until the screen displays the battery resistance meter. This function can detect internal resistance
per cell and total resistance.

6  

 5   6 

m

Ω

6

6

7

m

Ω

T o t a l

:

 3 6 m

Ω

M A I N

 2 3

.

8 6 V

H

3

.

9 9 3

   

L

3

.

9 4 6 V

highest
voltage

Battery resistance is a major technical index of battery performance. Normally low resistance means great discharge
capacity, or the otherwise. 
After long-term usage, activity of internal chemicals will decrease, while internal resistance will increase. Detecting
battery internal resistance could help better understand battery health condition.

3

.

9 7

3

.

9 9

3

.

9 5 V

3

.

9 9

3

.

9 9

3

.

9 7 V

6  

 5   6 

m

Ω

6

6

7

m

Ω

PACKAGING CONTENT

Pc1260 Charger Unit *1

Power Cord *1

Data Cable *1

12S Battery Balance Board *2

Instruction Manual *1

Instruction

Manual

5

5

OPTIONAL PARTS

 *(Below parts are excluded in the package)

SK-600119-03

SK-600119-04

AS150 (Female connector with male case)

SK-600119-05

AS150 (Female connector with male case)
+XT150 Male connector

AS150 (Male connector with female case)

lowest
voltage

Check if the connection between battery main port and charger is correct
Check if the battery main port voltage is normal

Check if the voltage of battery main port and balance port is normal

Check if the connection between battery balance port and charger is correct
Check if the balance port voltage is normal

Check if the battery is already fully charged

Check if the battery polarity is reversed

Check if the fan works normally, or the environmental temperature is high

Charging capacity is beyond default setting or user setting

Charging time is beyond default setting or user setting

B A T T E R Y

M E T E R

F U E L

G A U G E

7 6

%

B A T T R E S I S T A N C E

S Y S T E M

 

S E T U P

S a f e t y

T i m e r

O N

1 2 0 M i n

C a p a c i t y O u t - O f f
O N

3 0 0 0 0 m A h

K e y  B e e p      O N
B u z z e r         O N

Press and hold           for 3
seconds to 
restore factory setting

L o a d F a c t o r y S e t
            E N T E R 

Charger version checking

V e r s i o n
H W : 1 . 2   S W : 1 . 0 5

Charging Time
Protection
(1-720 minutes)

Charging Capacity
Protection
(1-50000mAh)

N O B A T T D E T E C T E D

C E L L S V O L T A G E H I
C H E C K M A I N P O R T

B A T T E R Y W A S F U L L

R E V E R S E P O L A R I T Y

O V E R T I M E L I M I T

I N T . T E M P T O O H I

O V E R C H A R G E

C A P A C I T Y L I M I T 

C O N N E C T E R R O R

C H E C K M A I N P O R T