5. Time limit setting by password
◆
Installer can set limited running time, when heat pump total running time reach preset time,
heat pump will be locked, can’t start to work anymore.
◆
Time limit setting can be removed, details can be consulted operating panel introduction.
6. Water tank temperature display correction function
◆
If F3 setting is 0, water tank temperature display correction function is invalid.
◆
If F3 setting is not 0, water tank temperature display temp = water tank real temp + F3
7. When electric heater working only, circulating water pump can be forced to start.
If F2 setting is 1, when electric heater start, circulating water pump will start 3sec in advance.
When electric heater stops, circulating water pump will delay 3sec to stop. Factory setting of F2
is 1.
8. Reserved ports on PC board
Programming port: convenient to download the site program.
Rs485 port: Open type RS485-RTU protocol port, convenient to extend system function. Such
as, add remote telephone controlling module, heat pump can be controlled by telephone. If
connect RS485 port to computer, heat pump can be controlled by controlling centre of computer.
Part 6. Details of PC board
1. DIP switch
Switch code
1
2
3
4
Off (figure side) 3phase H cooling
Air source
Hot water
ON
1phase
Only heating
Water source Swim pool
Other DIP switch
Heat pump No
Switch 5
Switch 6
Switch 7
Switch 8
Summary of Contents for SX-20BZA
Page 3: ......
Page 4: ......
Page 9: ...Buffertanks Skyline Energy 200Lt 3 zone buffertank dimensions April 2019...
Page 10: ...Buffertanks continued Skyline Energy 200Lt 2 zone buffertank dimensions April 2019...
Page 11: ...Buffertanks continued Skyline Energy 100Lt 2 zone buffertank dimensions April 2019...
Page 13: ......
Page 14: ......
Page 19: ...Typical installation diagram...
Page 23: ...Skyline Energy 200Lt buffertank Stainless Steel 2 zone or 3 zone...
Page 24: ...Typical 200Lt 2 zone buffertank installation...
Page 25: ...Typical V model heatpump installation...
Page 27: ...Typical V model heatpump installation Typical V model heatpump installation...
Page 29: ...Part 1 Operating panel introduction 1 Display interface 2 Buttons function Clock M power...