168
SJ6826RT, SJ6832RT
213560ABA
Section 5 – Procedures
Load Sensing System
▪
Select the “Yes” from the menu by press the
ENTER
button.
18.
The display will show “
Calibrate Level: Tilt 0.0’ , 0.0’
”.
▪
Select the “
ESCAPE
” from the menu once.
19.
The display will show “
Tilt Setups Calibrate Level
”.
▪
Select the “
ESCAPE
” from the menu once again.
20.
The display will show “
Setups Tilt Setups
”.
▪
By using Left/Right buttons, select the “Load Setups” from the menu and press the
ENTER
button.
21.
The display will show “
Load Setups: Calibrate Load
”.
▪
Select the “
Load Setups: Calibrate Load
” from the menu and press the
ENTER
button.
22.
At this point, elevate the aerial platform at full height, check the harness and making sure it is not stretched
tight, then lower down the platform.
23.
The display will show “
Calibrate Load: Platform Down?
”.
▪
Asking for confirmation that the platform is fully lowered?
▪
Check that the platform is fully lowered then press the
ENTER
button to confirm.
24.
The display will show “
Calibrate: Loaded Empty? No
”.
▪
Asking for confirmation that the platform is empty?
▪
Check that the platform is empty
25.
By using the Up/Down buttons, enter the “Yes” followed by pressing the
ENTER
button.The display will
show “
Calibrate Load: Please Lift......
”.
▪
Waiting for the lift switch to be activated.
26.
Hold the lift switch and keep holding it until the platform is fully elevated.
IMPORTANT
If the lift switch is released earlier than full-height position, the
calibration will have to be aborted and repeated from the beginning!
27.
When the system detects the lift switch closed, the display shows
Calibrate Load: Lift Empty
.
28.
After a delay, the system stops the platform lifting and takes height and pressure measurements. The
display shows
MEASURING # xx
When the measurements have been taken, the platform resumes lifting.
NOTE
The Lifting, stopping,measuring,lifting process
continues until the platform reaches full height .
29.
When the platform reaches full height release the lift switch.
30.
The display briefly shows
TOTAL DATA: 04
to indicate the number of measurements taken.
31.
The display shows
Calibrate Load: Please Lower
.
IMPORTANT
If the lower switch is released earlier than full-
lower position, the calibration must be aborted and
repeated from the beginning!