Section 5 – Procedures
Outriggers
5.4-3 Auto-Leveling Outrigger Settings
and Error Codes
Reading the Codes:
Error codes are indicated with the flashing LED on the
control module. When there is a fault, the LED on the
outrigger control module flashes to indicate the error
code number.
Identify the error code by counting the flashes as
follows:
1.
The first digit is indicated by half-second flashes
followed by half-second pauses.
2.
A 2.5-second pause follows.
3.
The second digit is then indicated by half-
second flashes followed by half-second pauses.
4.
A 5-second pause follows, then the cycle
repeats.
Codes are continuously displayed by the LED until
the fault is cleared, the outrigger control module is
reset and no longer detects the fault, or idle timeout
becomes active.
Since the outrigger control module only reports one
error, only one code can be read from the LED per
instance. If the error is cleared and another error is
present, it will then be presented.
LED ERROR CODES
EVERYTHING OK
ON
VEHICLE TILTED
1/1
OUTRIFFERS CANNOT BE MOVED!
1/2
OUTRIGGERS NOT HOME
2/2
NOT FULLY LEVEL
2/1
RELEASE OUTRIGGER DEMAND!
5/5
CHECK OUTRIGGER SUPPLY (P4-9)
5/2
CANNOT LEVEL: BAD TILT SENSOR
7/1
OUTRIGGERS MANUALLY CONTROLLED!
8/8
TESTING HWFS
7/8
B+ SUPPLY TOO LOW
5/1
STARTUP!
7/7
FAULT: BAD SLAVE MICRO
7/5
FAULT: BAD TILT SENSOR
7/1
FAULT: BAD HWFS
7/2
FAULT: P2-5 FAULTY
8/1
FAULT: P2-6 FAULTY
8/2
FAULT: P2-9 STUCK ON
8/3
FAULT: P2-8 ALWAYS ON
8/4
FAULT: P2-8 ALWAYS OFF
8/5
FAULT: HWFS STALLED!
7/8
1436AC