165
SJ6826RT, SJ6832RT
213560ABA
Load Sensing System
Section 5 – Procedures
5.5-2 Machine Level Calibration
Procedure
IMPORTANT
Each phase must be completed before the next
phase can be carried out. All phases must be
completed before the aerial platform can be
operated. Always follow the instructions of the
Calibration instrument.
1.
Ensure aerial platform is parked on a firm and
level surface.
2.
Elevate the scissors high enough to lay a level
across the base tubes. Ensure there is no debris
on the base and the level sits flat. Do not elevate
aerial platform higher than the high speed/tilt
override limit switch.
3.
Manually operate the outriggers and level the
machine in 4 places: left side, right side, front
and rear. All 4 outriggers must be firmly placed
and all 4 tires are off the ground.
4.
Double check that the aerial platform is level at
all 4 points.
5.
Connect the EZcal tool to the P1 connector on
the
CONTROL MODULE
.
6.
The display will show
Help: Press Enter
.
Access Level Procedure
7.
By using Left/Right buttons, select the
Access
Level (3 )
from the menu and press the
ENTER
button.
8.
The display will show
Access Level: Code
(0000)
.
9.
By using the Up/Down buttons, enter the
Access Level Code (1
1
2
2) followed by
pressing the
ENTER
button.
10.
The display will show
Access Level 2
. By using
Left/Right buttons, select the
Setups
from the
menu and press the
ENTER
button.
11.
The display will show
Setups: Change Defaults
.
Select the
Change Defaults
from the menu and
press the
ENTER
button.
12.
The display will show
Defaults, 0 = Custom
.
By using Up/Down buttons, select the Defaults:
Code Setting for your Model (For default code,
refer to
5 .5-9 Curved/Group codes chart )
from
the menu.
13.
Press
ENTER
and followed by
ESCAPE
.
Calibrate Level Procedure
14.
The display will show
Setups Change Defaults
.
By using Left/Right buttons, select the
Calibrate
Level
from the menu and press the
ENTER
.
15.
The display will show
Calibrate Level: Yes:
Enter, No: ESC
. Select the
Yes
from the menu
by press the
ENTER
button.
16.
The display will show
Calibrate Level: Tilt
0.0’ , 0.0’
. Select the
ESCAPE
from the menu
once.
17.
The display will show
Setups Calibrate Level
Select the
ESCAPE
from the menu once again.
18.
The Calibration procedure is complete, unplug
and remove the EZcal.
19.
Close the hydraulic/electric cabinet.