137
SJ6826RT, SJ6832RT
213560ABA
General
Section 5 – Procedures
3.
Psi should
match serial plate
or
1.
2.
3.
Tighten the jam nut and apply a dab of torque
seal where the jam nut and adjuster screw meet.
4.
Remove the pressure gauge and reconnect the
control box to the platform.
5.2-11 Lift Pressure Setting
Checking the Pressure
1.
Bring the control box down from the platform to
the ground so it will be accessible while working
5 .2-6 Reconnecting the Platform Control Box for
Use from the Ground
.
2.
Refer to the aerial platform’s serial plate for the
correct lift pressure for the unit.
3.
The lift manifold hose and port is located on the
rear side of the main manifold in the tank side
cabinet. To access it, release the latch beside
the manifold, then using the handle, tip the
manifold forward.
4.
With an oil pan and rag handy, disconnect the
hose, capping off or plugging both the hose and
the fitting on the manifold.
Release the latch
Use handle
to tip the
manifold
forward
Cap lift fitting
and plug
hose end
5.
Connect a pressure gauge to the quick
disconnect fitting located on the top of the main
manifold.
Pressure gauge
attached to quick
disconnect fitting
Lift pressure
relief valve
To
order