background image

 

SkyAzúl, Equipment Solutions   

 

  www.skyazul.com  

  

 

             301-371-6126 

 
 
 
 

NOTICE 

 
SkyAzúl makes no warranty of any kind with regard to this material, including, but not limited to, the 
implied warranties of merchantability and/or its fitness for a particular purpose. 
 
SkyAzúl will not be liable for errors contained in this manual or for incidental or consequential 
damages in connection with the furnishing, performance, or use of this manual. This document 
contains proprietary information, which is protected by copyright, and all rights are reserved. 
 
No part of this document may be photocopied, reproduced, or translated to another language without 
the prior written consent of SkyAzúl. 
 
SkyAzúl reserves proprietary rights to all drawings, photos and the data contained therein. The 
drawings, photos and data are confidential and cannot be used or reproduced without the written 
consent of SkyAzúl.  The drawings and/or photos are subject to technical modification without prior 
notice. 
 
All information in this document is subject to change without notice. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

SkyAzúl, Inc. 

16 Walnut Street 
Middletown, MD 21769 
Fax  301-371-0029 

[email protected]

 

 

Summary of Contents for Trimble/LSI GM820

Page 1: ...Trimble LSI GM820 Volvo With GS820 Display and Wireless Sensors Installation and Service Manual...

Page 2: ......

Page 3: ...y information which is protected by copyright and all rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of...

Page 4: ......

Page 5: ...tion lockout at 110 C Slope indicator show the pipelayer level d Slew indicator the arrow points toward the uphill direction The quadrant refers to the pipelayer upper body position The left side of t...

Page 6: ...using Back next up and Down as described in password settings section and press enter alarm red lamp level All programmed and rated capacity limits and two block will generate an audible alarm when t...

Page 7: ...e is available B0211_V1012 Sxxx zip It contains all the language packs mentioned above example if a system with the default language pack must be switched to Chinese 1 Download the language packs if i...

Page 8: ...t be in contact with any metal object d The transmitter antenna should point to the left of the boom when viewed from the cab it should not point directly to or away from the display 2 Weld the mounti...

Page 9: ...and clear the sensor chain and weight b Hoist slowly until the buzzer sounds Note the hoisting distance remaining this distance must be great enough to allow the operator and the lockout system if in...

Page 10: ...t angle indication accordingly 2 4a angle calibration procedure 1 Mechanical Set up 1 Level the boom such that it is perfectly horizontal use a high quality bubble or digital angle sensor If the LMS d...

Page 11: ...araMeter aDjuStMent 5 Use up and Down to select the angle sensor to be calibrated and press enter 6 Select 2 triM and press enter to modify 7 Use up and Down to modify the trim value example If angle...

Page 12: ...Determine the sensor to be removed If more than one sensor of the same type has been added to the sensor list then determine the radio identification number ID of the sensor to be removed before proce...

Page 13: ...munication with the sensor is possible and to start the wizard 4 Use up and Down to adjust the actual parts of line on the load sensor and then press enter to confirm 5 Note the units that will be use...

Page 14: ...ed 4 Verify list and trim angle indication in the operation display They should change as shown in the picture For calibration use one of the two procedures below Minimum and maximum limits for list a...

Page 15: ...o to menu 4 inStallation and select 4B SenSor caliBration 3 Enter the user password aza and press enter 4 Select 4B1 autoMatic caliBration WizarD 5 Use up and Down to select the trim or list sensor 6...

Page 16: ...de the data logger analyzes the measured weight and records the peak value only One threshold per load cell must be adjusted When the weight drops by more than the peak threshold the peak weight is re...

Page 17: ...nd will then have teh same ID It is the case for the load and anti two block A2B and for the trim list angles how to restore default factory settings It is possible to return the display to its factor...

Page 18: ...Alternatively to the above access menu 5e digital input to see the status of the two digital input signals No 1 Mute input Off On No 2 Rigging mode input Off On System Sensors Diagnostic 1 Go to menu...

Page 19: ...dition Verifythewireconnection RefertothePowerSupply and Lockout Connection sub section of this manual alert VeriFy White Wire ShorteD to GrounD description Voltage is not detected on the lockout wire...

Page 20: ...on the key but its size is 0 kB Solution Did the transfer complete successfully Try again Problem The following message appears on screen during the transfer unaBle to create File replace uSB Solutio...

Page 21: ...b Only dtl files generated by the LMS data logger can be displayed 4 3c Full report To export the full report to Excel click on the Full Report button in the tool bar table Full report column headings...

Page 22: ...do not overtighten 5 5 MainTenanCe MainTenanCe 1 4 in 1 2 Hex key 5 32 in Flat bladed screwdriver 5 New high quality D cell battery 3 6 V lithium or alkaline Figure remove the sensor box from the moun...

Page 23: ...e the white nylon hex bolt to the middle of the length of the new antenna 8 Coat the exposed metal foot of the new antenna with an electrical insulating compound by carefully inserting it in the mouth...

Page 24: ...o corrosion is visible on the battery holder inside the load cell transmitter If some trace of corrosion is visible rub it off gently and put a small amount of dielectric grease on each battery holder...

Page 25: ...length of a length sensor 3 Verify radio communication see Radio communication troubleshooting section Battery diagnostic Go to menu 5a SySteM SenSorS DiaGnoStic Select a sensor and press enter to ver...

Page 26: ...ad length parallel 16F Sheave radius 16G Deduct 4D chart SettinGS 1 Rated capacity indicator 2 Pipelayer capacity chart interpolation 3 Out of charts default working load limit 4 Enable start section...

Page 27: ...noStic 5a SySteM SenSorS 5B raDio netWork 5B1 RADIO NETWORk 5B2 LAST SENSORS RECEIVED 5B3 SEARCh FOR SENSORS 5B4 BIT ERROR RATE TEST 5c lockout 1 A2B AND OVERLOAD 2 FREE SWING CUT 3 MUTE INPUT 4 RIGGI...

Page 28: ......

Page 29: ......

Page 30: ...2 SkyAz l Equipment Solutions www skyazul com 301 371 6126 SkyAz l Inc 16 Walnut Street Middletown MD 21769 Phone 301 371 6126 Fax 301 371 0029 info skyazul com www skyazul com...

Reviews: