User manual / Handbuch / Navod k obsluze
METIS 4
Measurements done according to the EN standard 926-2 |2013 (measured under a tension of 50N) Tolerance: +/- 1 cm
LINE SPECIFICATIONS
| METIS 4 - 40
NAME
QUANTITY
MATERIAL
LL LENGTH
WIRE LENGTH
A1
2
7850-100-222
190,4
836,3
A2
2
7850-100-222
181,1
827
A3
2
7850-100-222
185,5
831,4
AU1
2
Cousin DU 1,9 red
646,9
reinforced
A4
2
7850-100-222
195,1
827,9
A5
2
7850-100-222
185,9
818,7
A6
2
7850-100-222
189,8
822,6
AU2
2
Cousin DU 1,9 red
633,8
reinforced
A7
2
7850-080-222
198,2
818,7
A8
2
7850-080-222
188,2
808,7
A9
2
7850-080-222
189,5
810
AU3
2
Cousin DU 1,5 red
579,3
reinforced
A10
2
7850-080-222
193,3
799,9
A11
2
7850-080-222
176,8
783,4
A12
2
7850-080-222
170,1
776,7
AU4
2
Cousin DU 1,5 red
565,4
reinforced
AUear
2
Cousin Ultimate 2.1
43,1
B1
2
7850-100-372
190,5
825,6
B2
2
7850-100-372
181,1
816,2
B3
2
7850-100-372
185,3
820,4
BU1
2
Cousin DU 1,9 blue
636,1
reinforced
B4
2
7850-100-372
194,9
816,8
B5
2
7850-100-372
186
807,9
B6
2
7850-100-372
190
811,9
BU2
2
Cousin DU 1,9 blue
622,9
reinforced
B7
2
7850-080-372
197,1
808
B8
2
7850-080-372
188,2
799,1
B9
2
7850-080-372
190,4
801,3
BU3
2
Cousin Ultimate 1.5
611,7
reinforced
B10
2
7850-080-372
191,5
792,6
B11
2
7850-080-372
176,9
778
NAME
QUANTITY
MATERIAL
LL LENGTH
WIRE LENGTH
B12
2
7850-080-372
169,9
771
BU4
2
Cousin Ultimate 1.5
601,9
reinforced
C1
2
7850-080-304
190,3
829,1
C2
2
7850-080-304
180,9
819,7
C3
2
7850-080-304
185,2
824
CU1
2
Cousin DU 1,9 violet
639,5
C4
2
7850-080-304
194,7
820,5
C5
2
7850-080-304
185,8
811,6
C6
2
7850-080-304
189,9
815,7
CU2
2
Cousin DU 1,9 violet
626,5
C7
2
7850-080-304
196,9
812
C8
2
7850-080-304
188,1
803,2
C9
2
7850-080-304
190,3
805,4
CU3
2
Cousin DU 1,5 violet
615,7
C10
2
7850-080-304
191,6
800,8
C11
2
7850-080-304
176,7
785,9
C12
2
7850-080-304
167,6
776,8
CU4
2
Cousin DU 1,5 violet
609,8
D1
2
7850-080-400
191,7
845,7
D2
2
7850-080-400
182,2
836,2
D3
2
7850-080-400
186,4
840,4
DU1
2
Cousin DU 1,5 green
654,6
D4
2
7850-080-400
195,4
836,6
D5
2
7850-080-400
186,1
827,3
D6
2
7850-080-400
189,8
831
DU2
2
Cousin DU 1,5 green
641,8
D7
2
7850-080-400
197,1
826,2
D8
2
7850-080-400
187,4
816,5
D9
2
7850-080-400
188,8
817,9
DU3
2
Cousin DU 1,5 green
629,7
A13
2
7850-080-400
135,2
752,5
NAME
QUANTITY
MATERIAL
LL LENGTH
WIRE LENGTH
B13
2
7850-080-400
131,7
749
C13
2
7850-080-400
139,3
756,6
SO1
2
7850-080-400
154,4
SA
2
7850-080-400
114,3
731,6
SB
2
7850-080-400
113
730,3
SC
2
7850-080-400
115,5
732,8
SD
2
7850-080-400
122,6
739,9
SO2
2
7850-080-400
154,4
SU
2
Cousin DU 1,5 green
463,9
on D riser
F1
2
7850-080-114
161,6
925,7
F2
2
7850-080-114
138,8
902,9
F3
2
7850-080-114
123,5
887,6
F4
2
7850-080-114
115,1
879,2
FO1
4
7850-080-114
197,9
FOU1
2
7850-100-114
283,5
F5
2
7850-080-114
132,3
865,9
F6
2
7850-080-114
118,4
852
F7
2
7850-080-114
111,3
844,9
F8
2
7850-080-114
110,5
844,1
FO2
4
7850-080-114
169,4
FOU2
2
7850-100-114
281,5
F9
2
7850-080-114
134,8
836,1
F10
2
7850-080-114
119,4
820,7
F11
2
7850-080-114
105,4
806,7
F12
2
7850-080-114
92,5
793,8
F13
2
7850-080-114
86,4
787,7
FO3
4
7850-080-114
137,1
FOU3
2
7850-100-114
281,5
FU
2
7850-240-114
281,5
mark at 30 cm
User manual / Handbuch / Manuel / Návod k obsluze
AYA
LINE SPECIFICATIONS |
AYA L
LL Lenght (loop-loop)
1) Before checking the wire length, pre-tension the line by the load of 22 kilograms for about
3 seconds per each line.
2) Always measure the wire length only when the line is tensioned by 5 kilograms.
3) If you need to cut the new line, the line has to be stabilized by the tension of 22 kilograms
and only then could be cut under the tension of 5 kilograms.
NAME
QUANTITY MATERIAL
LL LENGTH
WIRE LENGTH
Certification glider
A1
2
PPSL 120 red
195,6
741,2
741,1
A2
2
PPSL 120 red
192,5
738,1
738,1
AU1
2
7850-200-222
492,4
A3
2
PPSL 120 red
179,2
732,1
731,9
A4
2
PPSL 120 red
177,4
730,3
730,0
AU2
2
7850-200-222
499,7
A5
2
7850-080-222
209,7
720,8
720,4
A6
2
7850-080-222
196,6
707,7
707,1
A7
2
7850-080-222
189,5
700,6
700,0
AU3
2
7850-160-222
457,9
B1
2
PPSL 120 blue
193,2
730,7
730,5
B2
2
PPSL 120 blue
190,1
727,6
727,4
BU1
2
7850-200-372
484,3
B3
2
PPSL 120 blue
176,5
722,4
722,1
B4
2
PPSL 120 blue
175,6
721,5
721,1
BU2
2
7850-200-372
492,7
B5
2
7850-080-372
206,4
715,6
715,4
B6
2
7850-080-372
195,7
704,9
704,6
B7
2
7850-080-372
189,5
698,7
698,4
BU3
2
7850-160-372
456,0
NAME
QUANTITY MATERIAL
LL LENGTH
WIRE LENGTH
Certification glider
C1
2
7850-080-304
202,7
739,7
739,1
C2
2
7850-080-304
199,7
736,7
735,9
D1
2
7850-080-400
215,9
752,9
752,3
D2
2
7850-080-400
213,0
750,0
749,3
CU1
2
7850-160-304
483,9
C3
2
7850-080-304
192,8
731,8
731,3
C4
2
7850-080-304
191,7
730,7
730,0
D3
2
7850-080-400
205,0
744,0
743,5
D4
2
7850-080-400
202,9
741,9
741,4
CU2
2
7850-160-304
485,9
C5
2
7850-080-304
225,5
723,7
723,2
C6
2
7850-080-304
214,5
712,7
712,0
C7
2
7850-080-304
205,5
703,7
703,3
CU3
2
7850-160-304
445,0
SA
2
7850-080-400
106,2
662,7
662,3
SB
2
7850-080-400
105,4
661,9
661,3
SC
2
7850-080-400
107,2
663,7
663,3
SD
2
7850-080-400
113,6
670,1
669,5
SU
2
7850-160-400
503,3
NAME
QUANTITY MATERIAL
LL LENGTH
WIRE LENGTH
Certification glider
F1
2
7850-080-114
249,5
779,8
779,7
F2
2
7850-080-114
220,4
750,7
750,9
F3
2
7850-080-114
208,9
739,2
739,5
FOU1
2
7850-100-114
271
F4
2
7850-080-114
208,7
725,2
725,2
F5
2
7850-080-114
194
710,5
710,7
F6
2
7850-080-114
193
709,5
709,5
FOU2
2
7850-100-114
257,2
F7
2
7850-080-114
160,4
703,1
703,2
F8
2
7850-080-114
148,9
691,6
691,9
F9
2
7850-080-114
142,4
685,1
685,6
FOU3
2
7850-100-114
283,4
FU
2
7850-240-040
253,7
Total length measured from the underside of the wing to the inner edge of the risers base with a tension of 50 [N].
Tolerance: +/- 1 cm
40
1. Before checking the wire length, pre-tension the line by the load of 22 kilograms for
about 3 seconds per each line.
2. Always measure the wire length only when the line is tensioned by 5 kilograms.
3. If you need to cut the new line, the line has to be stabilized by the tension of
22 kilograms and only then could be cut under the tension of 5 kilograms.
LL Lenght (loop-loop)
Wire length
31