User manual / Handbuch / Navod k obsluze
FLEXOR
LINE SPECIFICATIONS
| FLEXOR – 27 m
2
NAME
QUANTITY
MATERIAL
LL LENGTH
WIRE LENGTH
A1
2
7850-080-222
86,9
692,6
A2
2
7850-080-222
82,9
688,6
AO1
2
PPSL 160 red
244,4
A3
2
7850-080-222
82,9
685,9
A4
2
7850-080-222
84,5
687,5
AO2
2
PPSL 160 red
241,6
AU1
2
6843-240-222
362,5
A5
2
7850-080-222
70,2
686,5
A6
2
7850-080-222
67,7
683,9
AO3
2
PPSL 160 red
226,9
A7
2
7850-080-222
67,7
681,9
A8
2
7850-080-222
68,9
683,1
AO4
2
PPSL 160 red
224,8
AU2
2
6843-240-222
390,6
A9
2
7850-080-222
67,5
672,9
A10
2
7850-080-222
62
667,4
AO5
2
PPSL 120 red
137
A11
2
7850-080-222
61,9
656,4
A12
2
7850-080-222
58,1
652,6
AO6
2
PPSL 120 red
126,1
AU3
2
6843-200-222
469,6
B1
2
7850-080-372
85,8
683,5
B2
2
7850-080-372
81,8
679,5
BO1
2
PPSL 160 blue
241,1
B3
2
7850-080-372
81,8
677,1
B4
2
7850-080-372
83,6
678,9
BO2
2
PPSL 160 blue
238,7
BU1
2
6843-280-379
357,8
B5
2
7850-080-372
69,1
678,7
B6
2
7850-080-372
67
676,6
BO3
2
PPSL 160 blue
224
B7
2
7850-080-372
67
675,8
B8
2
7850-080-372
68,6
677,4
BO4
2
PPSL 160 blue
223,3
BU2
2
6843-280-379
386,8
B9
2
7850-080-372
66,6
667,9
B10
2
7850-080-372
61,6
663
BO5
2
PPSL 120 blue
135,6
NAME
QUANTITY
MATERIAL
LL LENGTH
WIRE LENGTH
B11
2
7850-080-372
61,4
652,9
B12
2
7850-080-372
57,9
649,3
BO6
2
PPSL 120 blue
125,7
BU3
2
6843-230-379
466,9
C1
2
7850-080-304
86,8
692,5
C2
2
7850-080-304
82,9
688,6
CO1
2
PPSL 120 violet
244,1
C3
2
7850-080-304
82,9
686,1
C4
2
7850-080-304
84,7
687,9
CO2
2
PPSL 120 violet
241,7
CU1
2
6843-230-248
362,5
C5
2
7850-080-304
70
687,6
C6
2
7850-080-304
67,8
685,3
CO3
2
PPSL 120 violet
226,9
C7
2
7850-080-304
67,8
684,3
C8
2
7850-080-304
69,3
685,8
CO4
2
PPSL 120 violet
225,8
CU2
2
6843-230-248
391,7
C9
2
7850-080-304
67,3
674,6
C10
2
7850-080-304
61,8
669,1
CO5
2
PPSL 120 violet
136,7
C11
2
7850-080-304
61,7
657,6
C12
2
7850-080-304
57,2
653,2
CO6
2
PPSL 120 violet
125,3
CU3
2
6843-180-304
471,5
D1
2
7850-080-400
88,6
707,5
D2
2
7850-080-400
84,7
703,7
DO1
2
PPSL 120 green
249,3
D3
2
7850-080-400
84,8
701,4
D4
2
7850-080-400
86,5
703,1
DO2
2
PPSL 120 green
247
DU1
2
6843-180-400
370,5
D5
2
7850-080-400
71,6
702,4
D6
2
7850-080-400
69,2
700
DO3
2
PPSL 120 green
231,8
D7
2
7850-080-400
69,3
698,2
D8
2
7850-080-400
70,4
699,4
DO4
2
PPSL 120 green
230
NAME
QUANTITY
MATERIAL
LL LENGTH
WIRE LENGTH
DU2
2
6843-180-400
399,9
D9
2
7850-080-400
71,4
686,8
D10
2
7850-080-400
65,2
680,6
DO5
2
PPSL 120 green
144,8
D11
2
7850-080-400
65,1
667,6
D12
2
7850-080-400
59,7
662,1
DO6
2
PPSL 120 green
131,8
SA
2
7850-080-400
132,4
626,6
SB
2
7850-080-400
131,8
626
SC
2
7850-080-400
136,3
630,4
SD
2
7850-080-400
145,5
639,4
SU
2
6843-180-400
494,6
on B riser
SFU
2
PPSL 120 violet
642,7
control length of the
SFU line itself
F1
2
7850-080-114
139,2
811
F2
2
7850-080-114
117,1
788,8
FO1
2
7850-080-114
127,3
F3
2
7850-080-114
117,3
772,7
F4
2
7850-080-114
110,1
765,5
FO2
2
7850-080-114
110,9
FOU1
2
7850-100-114
207,5
F5
2
7850-080-114
103,6
751,5
F6
2
7850-080-114
90
737,9
FO3
2
7850-080-114
114,9
F7
2
7850-080-114
90,9
730,5
F8
2
7850-080-114
89,7
729,3
FO4
2
7850-080-114
106,6
FOU2
2
7850-100-114
196,1
F9
2
7850-080-114
81,5
712,1
F10
2
7850-080-114
69,1
699,7
FO5
2
7850-080-114
114,3
F11
2
7850-080-114
47,6
683,6
F12
2
7850-080-114
39
675
FO6
2
7850-080-114
119,7
FOU3
2
7850-100-114
179,4
FU
2
7850-200-114
338,4
mark at 25 cm
1. Before checking the wire length, pre-tension the line by the load of 22 kilograms for
about 3 seconds per each line.
2. Always measure the wire length only when the line is tensioned by 5 kilograms.
3. If you need to cut the new line, the line has to be stabilized by the tension of
22 kilograms and only then could be cut under the tension of 5 kilograms.
User manual / Handbuch / Manuel / Návod k obsluze
AYA
LINE SPECIFICATIONS |
AYA L
LL Lenght (loop-loop)
1) Before checking the wire length, pre-tension the line by the load of 22 kilograms for about
3 seconds per each line.
2) Always measure the wire length only when the line is tensioned by 5 kilograms.
3) If you need to cut the new line, the line has to be stabilized by the tension of 22 kilograms
and only then could be cut under the tension of 5 kilograms.
NAME
QUANTITY MATERIAL
LL LENGTH
WIRE LENGTH
Certification glider
A1
2
PPSL 120 red
195,6
741,2
741,1
A2
2
PPSL 120 red
192,5
738,1
738,1
AU1
2
7850-200-222
492,4
A3
2
PPSL 120 red
179,2
732,1
731,9
A4
2
PPSL 120 red
177,4
730,3
730,0
AU2
2
7850-200-222
499,7
A5
2
7850-080-222
209,7
720,8
720,4
A6
2
7850-080-222
196,6
707,7
707,1
A7
2
7850-080-222
189,5
700,6
700,0
AU3
2
7850-160-222
457,9
B1
2
PPSL 120 blue
193,2
730,7
730,5
B2
2
PPSL 120 blue
190,1
727,6
727,4
BU1
2
7850-200-372
484,3
B3
2
PPSL 120 blue
176,5
722,4
722,1
B4
2
PPSL 120 blue
175,6
721,5
721,1
BU2
2
7850-200-372
492,7
B5
2
7850-080-372
206,4
715,6
715,4
B6
2
7850-080-372
195,7
704,9
704,6
B7
2
7850-080-372
189,5
698,7
698,4
BU3
2
7850-160-372
456,0
NAME
QUANTITY MATERIAL
LL LENGTH
WIRE LENGTH
Certification glider
C1
2
7850-080-304
202,7
739,7
739,1
C2
2
7850-080-304
199,7
736,7
735,9
D1
2
7850-080-400
215,9
752,9
752,3
D2
2
7850-080-400
213,0
750,0
749,3
CU1
2
7850-160-304
483,9
C3
2
7850-080-304
192,8
731,8
731,3
C4
2
7850-080-304
191,7
730,7
730,0
D3
2
7850-080-400
205,0
744,0
743,5
D4
2
7850-080-400
202,9
741,9
741,4
CU2
2
7850-160-304
485,9
C5
2
7850-080-304
225,5
723,7
723,2
C6
2
7850-080-304
214,5
712,7
712,0
C7
2
7850-080-304
205,5
703,7
703,3
CU3
2
7850-160-304
445,0
SA
2
7850-080-400
106,2
662,7
662,3
SB
2
7850-080-400
105,4
661,9
661,3
SC
2
7850-080-400
107,2
663,7
663,3
SD
2
7850-080-400
113,6
670,1
669,5
SU
2
7850-160-400
503,3
NAME
QUANTITY MATERIAL
LL LENGTH
WIRE LENGTH
Certification glider
F1
2
7850-080-114
249,5
779,8
779,7
F2
2
7850-080-114
220,4
750,7
750,9
F3
2
7850-080-114
208,9
739,2
739,5
FOU1
2
7850-100-114
271
F4
2
7850-080-114
208,7
725,2
725,2
F5
2
7850-080-114
194
710,5
710,7
F6
2
7850-080-114
193
709,5
709,5
FOU2
2
7850-100-114
257,2
F7
2
7850-080-114
160,4
703,1
703,2
F8
2
7850-080-114
148,9
691,6
691,9
F9
2
7850-080-114
142,4
685,1
685,6
FOU3
2
7850-100-114
283,4
FU
2
7850-240-040
253,7
Total length measured from the underside of the wing to the inner edge of the risers base with a tension of 50 [N].
Tolerance: +/- 1 cm
40
LL Lenght (loop-loop)
Wire length
Measurements done according to the EN standard 926-2 |2013 (measured under a tension of 50N) Tolerance: +/- 1 cm
39