DOL 534 • DOL 539
16
Circuit Diagrams and Cable Plans
3.1.5 Connection of seven or more I/O modules
A maximum of 10 I/O modules may be connected, of which 2 can be weighing modules.
When 7 or more I/O modules/weighing modules are connected, the flat cable is supplemented by two wires
(D)
with a minimum of 1.0 mm
2
between the internal power supply
(A)
and the terminal block on I/O module number
7.