DOL 534 • DOL 539
34
Circuit Diagrams and Cable Plans
5 Circuit diagrams
5.1 General information about circuit diagrams
Symbols are pursuant to the IEC/EN 60617 standard.
The classification of the symbols ("letter codes") on the symbols is pursuant to the IEC/EN 81346-2 standard.
Reference designations are in accordance with IEC/EN 81346-1:2001 structuring principles and reference des-
ignations. This standard indicates structured methods for naming electrotechnical systems.
5.1.1 Color code
Letter Code
Color
Standard
BK
Black
Color coding on wires are in accor-
dance with standard IEC 60757:
Letter codes to identify colors used
on drawings, diagrams, labelling,
etc.:
BN
Brown
RD
Red
OG
Orange
YE
Yellow
GN
Green
BU
Blue (incl. light blue)
VT
Violet (purple red)
GY
Grey (slate)
WH
White
PK
Pink
GD
Gold
TQ
Turquoise
SR
Silver
GNYE
Green-and-yellow
5.1.2 Power supply isolator
Power supply isolator
The installation of a power supply isolator is required for each motor and
motor control.
5.1.3 Letter Code
The letter codes used in accordance with standard IEC/EN61346-2.
-F
-K
-M
-Q
-S
-T
-W
Protective
equipment
RCCB / Initial
fuse Protective
motor switch
Controller
Contactor
Fan
Motor
Power supply
isolator
Switch
Motor con-
troller
Cable
Summary of Contents for DOL 539