DOL 534 • DOL 539
Circuit Diagrams and Cable Plans
35
5.1.4 Example of connection
Example: Connection of a DA74CV winch motor to controller K1
-K1.1
-K1.2
-K1.3
-K1.5
-K1.6
Terminal number
in controller
Power supply from controller:
+24V DC from
te24V max 0.8A on K1.6
0V from
terminal controller GND - on K1.6
Cable lead
Terminal
Cable name
Power supply from emergency opening
-K1.4
DA 74CV winch motor
-K1.6 loop module
Power supply from emergency opening 0V-1 = Q1 terminal in controller.
Power supply from emergency opening 24V-1 = Q2 or Q3 terminal in controller.
Power supply from emergency opening 24V-2 = Q4 or Q5 terminal in controller.
Power supply from emergency opening 24V-12 = F6 terminal in the controller/emergency opening.
In case of doubt, please contact Service or your dealer.