DA 820 LPC • DA 820 • ECT 820 • DCT 820 Fans
Technical User Guide
9
445036 DA 820 LPC 10 fan 230V1 50/60Hz TH
445039 DA 820 LPC 12 fan 230V1 50/60Hz TH
The fan is the same as part no. 445026/445028, but includes a thermal
cutout.
Cable for the thermal cutout is a separate cable.
DA 820 LPC 10 should not be used for negative pressure higher than 90
Pa.
DA 820 LPC 12 should not be used for negative pressure higher than 130
Pa.
445030 DA 820 ON/OFF fan High Flow 230V1 50Hz
445031 DA 820 ON/OFF fan High Flow 230V1 60Hz
445034 DA 820 ON/OFF fan Low Energy 230V1 50Hz
Motor 1.1 kW.
2 m cable.
3-blade, 1x230 V fan.
It cannot be Triac regulated, and it is therefore used as an ON/OFF fan.
High pressure stability, high performance, and relatively high energy con-
sumption and noise level.
The fan is primarily used where high working pressure is required, for in-
stance in connection with air cleaning, etc.
It comes with fan blades and fan suspension.
ErP 2015 approved.
DA 820 High Flow 50 Hz should not be used for negative pressure higher
than 130 Pa.
DA 820 High Flow 60 Hz should not be used for negative pressure higher
than 120 Pa.
DA 820 Low Energy 50 Hz should not be used for negative pressure higher
than 80 Pa.