DA 820 LPC • DA 820 • ECT 820 • DCT 820 Fans
62
Technical User Guide
445036 DA 820
LPC 10 1x230 V
w/thermal
cutout
445026 DA 820
LPC 10 1x230 V
445028 DA 820
LPC 12 1x230 V
445028 DA 820
LPC 12 1x230 V
w/thermal
cutout
Fan output
Revolutions per minute
RPM
1000
1170
Air output at 0 Pa
m
3
/h
24800
28800
Air output at -10 Pa
m
3
/h
24000
28300
Air output at -20 Pa
m
3
/h
23200
27700
Air output at -30 Pa
m
3
/h
22500
27100
Air output at -40 Pa
m
3
/h
21700
26400
Air output at -50 Pa
m
3
/h
20900
25700
Air output at -60 Pa
m
3
/h
20000
25100
Air output at -70 Pa
m
3
/h
19000
24400
Air output at -80 Pa
m
3
/h
17900
23600
Air output at -90 Pa
m
3
/h
16600
22900
Air output at -100 Pa
m
3
/h
-
22000
Air output at -110 Pa
m
3
/h
-
21100
Air output at -120 Pa
m
3
/h
-
20000
Air output at -130 Pa
m
3
/h
-
18800
Power consumption at
-10 Pa
W
808
1311
Specific output at -10 Pa
m
3
/kWh
29700
21600
Specific energy at -10
Pa
Watt/1000
m
3
/h
34
46
Testing body
SKOV A/S
Environment
Temperature, operation
°C (°F)
÷ 40 to + 40 (÷ 40 to 104)
Start temperature
°C (°F)
÷ 40 to + 50 (÷ 40 to 122)
Storage temperature
°C (°F)
÷ 40 to + 70 (÷ 40 to 158)
Ambient humidity, opera-
tion
% RH
10 - 95
Protection class
IP
Motor controller: IP 65 Fan motor: IP 55
Fan noise, outside
(2 m, 45 degrees)
dB (A)
69
73
Shipment
Motor controller - dimen-
sions H x W x D
mm
266 x 185 x 90
Fan - dimensions (H x W
x D)
mm
278 x 800 x 800
Weight
g
21432
Shipping weight
g
26117