DA 820 LPC • DA 820 • ECT 820 • DCT 820 Fans
10
Technical User Guide
445032 DA 820 ON/OFF fan High Flow 400V3 50Hz
445033 DA 820 ON/OFF fan High Flow 400V3 60Hz
445035 DA 820 ON/OFF fan Low Energy 400V3 50Hz
Motor 1.1 kW.
2 m cable.
3-blade, 3x400 V fan.
It cannot be Triac regulated, and it is therefore used as an ON/OFF fan.
High pressure stability, high performance, and relatively high energy con-
sumption and noise level.
The fan is primarily used where high working pressure is required, for in-
stance in connection with air cleaning, etc.
It comes with fan blades and fan suspension.
ErP 2015 approved.
DA 820 High Flow 50 Hz should not be used for negative pressure higher
than 130 Pa.
DA 820 High Flow 60 Hz should not be used for negative pressure higher
than 120 Pa.
DA 820 Low Energy 50 Hz should not be used for negative pressure higher
than 80 Pa.
445037 DA 820 ON/OFF fan Low Energy 230V1 50Hz TH
The fan is the same as part no. 445034, but includes a thermal cutout.
Cable for the thermal cutout is a separate cable.
DA 820 Low Energy 50 Hz should not be used for negative pressure higher
than 80 Pa.
409013 ECT 820-6 Triac/ON/OFF fan 230V1 50Hz
Motor 0.84 kW.
1.5 m cable.
3-blade, 1x230 V fan.
Can be used as a stepless Triac regulated fan and as an ON/OFF fan.
High output and good pressure stability.
It comes with fan blades and fan suspension.
ErP 2015 approved.
ECT 820- 6 Triac/ON/OFF 50 Hz should not be used for negative pressure
higher than 90 Pa.