Part
Description
Wedge
2.1 Mounting of sandwich screws
To ensure that the screw makes the right thickening and the best possible thread on the back, the correct
hole must be drilled first and the screwing must be done with the correct momentum depending on the
thickness of the metal in the sandwich wall.
Diameter of screw [mm]
Thickness of metal in
sandwich panel
[mm]
Size of holes in
sandwich panel
[mm]
Tightness
torque
[Nm]
5
0,63 - 0,75
Ø 3,8
2,5
0,75 - 0,88
Ø 4,1
3,0
0,88 - 1,00
Ø 4,2
3,5
1,00 - 1,25
Ø 4,3
3,5
1,25 - 1,50
Ø 4,4
4,0
3
Wall Inlet Positioning
The positioning of the inlet in a wall depends on the layout of the building and the house layout. The
positioning may therefore only be made according to directions communicated by SKOV A/S or
representatives of the company.
4
Installation in wall
The upper transportation screw at the centre of the flap should secure that the inlet box is not dislocated
sidewise when building in.
The DA 1200 is a plastic wall inlet and not as sturdy as a brick. When temperature changes plastic is
working considerably more than brickwork (up to 1.5 mm at a change of temperature of approx. 30 °C),
and consequently some conditions should be considered when handling and building in.
Summary of Contents for DA 1200 Wall Inlet
Page 5: ...2020 06 26 612321 PRODUCT SURVEY 1 General Drawing of DA 1200 Wall Inlet...
Page 27: ...2020 06 26 612321 6 6 Door set for Wire Rope Drive Min 40 cm Min 40 cm...
Page 30: ...7 3 DA 1200 Inlet Cover 7 4 DA 1200 Light Trap for Inlet Cover...
Page 31: ...2020 06 26 612321 7 5 DA 1200 fly screen for inlet cover...