45
SKOPE TME-N ActiveCore
Replacement Procedures
Service Manual
It is important that the fan blade and/or fan motor is replaced with the same
part to ensure safety, correct alignment and refrigeration performance, and
compliance. Fan blades should be tightened to the fan motor manufacturer
recommended torque settings (shown in the table below).
Fan motor manufacturer recommended torque settings
To access and remove the condenser fan assembly
To replace the fan blade
To replace the fan motor (with correct SKOPE spare part only)
Fan motor manufacturer Torque setting
Wellington Drive
1.5 Nm
1. Isolate the chiller from the power supply and remove the refrigeration unit
(see page 41).
2. Remove the unit cover (see page 44).
3. Open the electrics box and unplug the condenser fan motor plug (see
page 43).
4. Cut the cable ties
holding the cables along
the unit, and free up the
condenser fan motor
cable.
5. Remove the fan assembly (fan motor, fan blade, mounting brackets) from the
unit by lifting the shroud up and out.
1. Remove the condenser fan assembly (see above).
2. Remove the screw and washer from the centre of the fan blade, and lift the
blade from the motor.
3. Replace new blade and fix with 12mm flat washer and serrated head screw.
Tighten the blade to fan motor manufacturer recommended torque setting.
4. Reassemble unit and test.
1. Remove the condenser fan assembly and the fan blade (see above).
2. Unplug the fan flexible cord from the electrics box (see page 43).
3. Detach the fan motor from the fan mounting brackets by removing the four
screws from the mounting bracket.
4. Fit new motor and reattach fan blade with 12mm flat washer and serrated
head screw. Tighten the blade to 1.5Nm.
5. Reassemble unit, ensuring all cables are neatly cable tied away from the fan
blade, and test for correct operation.