41
SKOPE TME-N ActiveCore
Replacement Procedures
Service Manual
Removing the
Unit
Follow the steps below to remove the refrigeration unit from the cabinet.
Ensure the chiller is disconnected from the power supply before removing
the unit.
The unit is heavy and requires a minimum of two people to lift from the
cabinet. Steps or a platform about one metre high are suggested to allow the
unit to be safely lifted, carried and put down at waist height.
To remove the refrigeration unit
1. Unplug the chiller from the power supply.
2. Remove the top sign. If fitted with key locks, open the door/s and unscrew
the sign from the brackets below the sign.
3. Detach the electronic controller assembly from the top of the cabinet, and
clip it onto the top of the unit.
4. Remove electrics cover and unplug the mains supply plug and cabinet plugs.
Note:
The unit plugs (plugs feeding into the unit) and electronic controller
plugs (plugs feeding to the electronic controller assembly) do not need to be
unplugged.
5. Remove the sign back strip.
Note:
If necessary the sign sides can also be
removed.
6. Undo the two unit fixing screws (one on each side of the unit) and lift the unit
off the cabinet.
7. When refitting the unit, ensure:
The gasket on the top of the cabinet is in good condition.
The mains and cabinet plugs are reconnected.
The electrics cover is refitted.
The unit is re-fixed in place.
Sign side
Electronic
controller assembly
Sign back strip
Electrics
cover
Mains and
cabinet plugs
Sign side
Top sign