EML224N Operation and Installation Manual
SKIPPER
Electronics AS
Edition: 2020-22-05
Page 51 of 64
Chapter: 7. Specifications
Environmental according to IEC60945
Operator/Display Unit
AC Supply voltage
230 V (195 - 253 V AC) or 115 V (96 - 125 V AC).
DC supply voltage
24 V DC (20-32 V).
Power consumption
50 W at 24 V, 70 W at 230 V or 115 V.
Power failure relay
Change-over contact, max. 24 V 300 mA.
NMEA port
9 pin D-type. 2 inputs, 2 outputs.
Operating temperature
-15 - 55 degree C. To increase serviceability and lifetime,
we suggest the working temperature to be held at 0 - 40
degrees C.
Storage temperature
-20 - 70 degree C.
Humidity
10 - 90 % relative, no condensation.
Protection
IP 23.
Electronic Unit
AC Supply voltage
230 V (195 - 253 V AC) or 115 V (96 - 125 V AC).
DC supply voltage
24V DC (20-32 V).
Operating temperature
-15 - 55 degree C. To increase serviceability and lifetime,
we suggest the working temperature to be held at 0 - 40
degrees C.
Storage temperature
-20 - 70 degree C.
Protection
IP33.
Transducer (sensor)
Operating temperature
-15 - 55 degree C.
Storage temperature
-20 - 70 degree C.
Protection
Submerged, 6 bar.