Fig. 2.12. Screen Status, Menu 5
Soft key Name
Range/value
Default value
Description
Activate with
hidden button
1
MENU
1 - 6
5
Chosen menu number 5.
2
OUT NUM
1 - 3
1
Analogue output channel to be configured
by keys 3 - 6.
3
OUT MODE 0 - 10 V
4 - 20 mA
0 - 10 V
Output mode selection for this channel
(key 2).
4
OUT MODE ForAftWT,
Lateral/WT,
ResultWT
ResultWT
Speed parameter to be output at this
channel (key 2).
5
ANA MIN
-48.6 - 48.6 kn
0.0 kn
Speed value for minimum output at this
channel (key 2).
6
ANA MAX
-48.6 - 48.6 kn
30.0 kn
Speed value for maximum output at this
channel (key 2).