EML224N Operation and Installation Manual
SKIPPER
Electronics AS
Edition: 2020-22-05
Page 27 of 64
Chapter: 2. Operation
Fig. 2.16. Screen Calibration, Menu 3
Soft key Name
Range/value Default value
Description
Activate with
hidden button
1
MENU
1 - 3
3
Chosen menu number 3.
2
Not used.
3
SWAP
No, p-s, f-a,
p-s/f-a,
No
Sensor 180 degrees swap.
4
HEAD ERR
0.0 - 30.0 °
0.0 °
Installation angular error correction.
5
TRANSV. ERR 0.0 - 38.9 kn
0.0 kn
Installation transversal error
correction.
6
Not used.