EML224N Operation and Installation Manual
SKIPPER
Electronics AS
Edition: 2020-22-05
Page 23 of 64
Chapter: 2. Operation
Fig. 2.13. Screen Status, Menu 6
Functions described below can be used during commissioning period to test different outputs with constant,
user adjustable speed values.
Note:
When the test mode (SPD TEST) is activated, this will be indicated by
flashing “TEST” label in the lower left part of the screen.
Soft key
Name
Range/value
Default value Description
Activate with
hidden button
1
MENU
1 - 6
6
Chosen menu number 6.
2
SPD TEST
On/off
Off
Toggling test mode on/off.
Yes
3
LONG. SP
-40.0, -20.0,
-15.0, -10.0,
-5.0, 0.0, 5.0,
10.0, 15.0,
20.0, 40.0,
0.0 kn
Select test value of longitudinal speed.
4
TRANSV. SP
-5.0, -4.0,
-2.0, -1.0,
-0.5, 0.0, 0.5,
1.0, 2.0, 4.0,
5.0,
0.0 kn
Select test value of transversal speed.
5
DISTANCE
0.00, 9.99,
99.99, 999.99,
9999.99,
99999.99
0.00 NM
Select test value of distance.
6
Not used