Table 3
Table 2 The Vectometer shows different flow rate (in mm
3
per minute) according to the lubricant flow rate and the working frequency of the
micropump.
Setting [mm
3
/
stroke]
Micropump working frequency [stroke/minute]
2.5
6
8.5
10
20
30
60
90
120
150
180
3
7.5
18
25.5
30
60
90
180
270
360
450
540
5
12.5
30
42.5
50
100
150
300
450
600
750
900
10
25
60
85
100
200
300
600
900
1,200
1,500
1,800
15
37.5
90
127.5
150
300
450
900
1,350
1,800
2,250
2,700
20
50
120
170
200
400
600
1,200
1,800
2,400
3,000
3,600
25
62.5
150
212.5
250
500
750
1,500
2,250
3,000
3,750
4,500
30
75
180
255
300
600
900
1,800
2,700
3,600
4,500
5,400
45
112.5
270
382.5
450
900
1,350
2,700
4,050
5,400
6,750
8,100
60
150
360
510
600
1,200
1,800
3,600
5,400
7,200
9,000
10,800
90
225
540
765
900
1,800
2,700
5,400
8,100
10,800
13,500
16,200
30
Summary of Contents for VectoLub VE1B