Every outlet port has two quick-release con-
nectors (
† fig. 4
).
The lower connector holds the capillary
tube of the line (lubricant). The upper con-
nector (orange collar) holds the outer tube of
the coaxial line (air).
Cross-section view of the outlet port
1
Upper quick-release connector
2
Lower quick-release connector
3
Outer tube of the coaxial line
4
Capillary tube of the coaxial line
Fig. 4
1
3
4
2
• Pull out (ca. 10 cm) the capillary tube
from the coaxial line
• Insert the capillary tube into the outlet
port and fit it to the lower quick-release
connector (
† A fig. 5
).
• Pull slightly the capillary tube to check it is
correctly held.
• Insert the outer tube into the outlet port
and fit it to the upper quick-release con-
nector (
† B fig. 5
).
• Pull slightly the outer tube to check it is
correctly held.
Fig. 5
4.3.2 Connection coaxial line / projection
block
!
The coaxial line may be only con-
nected by authorized and trained
specialists.
!
The coaxial line can be connected
to the projection block only if it is
already connected to the outlet port of
the VE1B.
!
When mounting or dismounting,
never twist, bend or crush the co-
axial tube.
The length of the coaxial line between the
outlet port of the module and the nozzle has
to be between 1 and 5 m. For greater length,
please contact the SKF service center.