4.3 Outlet connection
4.3.1 Connection coaxial line / outlet port
!
The coaxial line may be only con-
nected by authorized and trained
specialists.
!
The coaxial line has first to be
connected to the outlet port of the
VE1B, and then to the nozzle.
!
It is recommended to identify an
outlet in accordance with the noz-
zle it supplies, e.g. with tubes of different
colors, with identification rings or
others.
The coaxial line (from 1 to 5 m*) is connect-
ed to the VE1B outlet port by means of
quick-release connectors.
*) For greater line length, please contact the SKF service center.
D A N G E R !
Before connecting the pump to
the compressed air feed ensure that the
main air valve is closed.
The compressed air quality must comply
with purity class 5 defined by DIN ISO
8573-1:
–
Maximum particle size: 5 µm
–
Maximum particle content: 10 mg/m
3
–
Pressure dew point: 7 °C
–
Maximum water content : 7 800 mg/m
3
–
Residual oil content max.: 25 mg/m
3
The VE1B systems have can be connected
to the user’s compressed air network via a G
1/4 port. The air inlet port is on the opposite
side of the one for lubricant.
4.2 Inlet connection
4.2.1 Lubricant inlet connection
If the VE1B unit has no integrated reservoir,
it has an inlet port G 1/4 for lubricant supply.
(
† fig. 1 page 16
)
4.2.2 Air inlet connection
The compressed air line must be connected
to the system in such a way that once
mounted, no force is applied to the pump (no
pressure on the connection).
It is important to use pipes that are suf-
ficiently long so that maintenance and re-
pairs can be carried out at a later time with-
out hindrance.
!
For the good function of a VE1B
unit, the air pressure inlet shall
not exceed 7 bars.