5. Assembly
- 38 -
951-181-022-EN
Version 03
5.8.7 Connecting a KFGS pump version with a cubical plug for 110-230 VAC power supply and an 8-pin pump bayonet plug, with ill
level monitoring, interim lubrication (MK/DK), and fault signal (-see KFGS operating instructions, 951-170-212-EN (Industrial)
Plug/assignment
Code
Function
DB file
X2
1
ZS (+)
Cycle switch/pressure switch
KFGS_230V.db
Load (path file)
Monitoring
=> System
=> Update
=>
KFGS_230V.db
2
ZS (signal)
Cycle switch/pressure switch
3
Not assigned
4
Not assigned
5
MK/DK
Machine contact/pressure contact (+)
6
MK/DK
Machine contact/pressure contact
7
SL2
Fault signal (GRD) (-)
8
SL2
Fault signal (+)
X1
1
L1
Main machine switch ON
2
N
Neutral lead
3
Plug without internal connection
PE
Grounding
Connecting the 8-pin adapter cable to
plug-in connection X2
• Connect pin 1 to LRM ZS/PS terminal
strip “Power ”
• Connect pin 2 to LRM ZS/PS terminal
strip “Ground connection -”
• Connect pin 5 to terminal strip “Power
” and to “OUT1”
• Connect pin 6 to terminal strip “OUT1
NO”
• Connect pin 7 to LRM relay “K2 pin A1”
and to terminal strip “Ground (GND)”
• Connect pin 8 to LRM relay “K2 pin A2”
• Connect plug X1 according to pump con-
nection diagram