5. Assembly
- 36 -
951-181-022-EN
Version 03
5.8.6 Connectivity for a KFGS pump version for 12-24 VDC power supply and 7-pin pump bayonet plug, with pump run monitoring,
machine or pressure contact, ill level monitoring, and interim lubrication (-see KFG operating instructions, 951-170-213-EN
(Vehicle))
Connecting the 7-pin adapter cable
• Connect pin 1 to LRM terminal strip
“GRD -”
• Connect pin 2 to LRM terminal strip
“Power ”
• Connect pin 3 to LRM terminal “OUT1
NO”
• Connect pin 4 to LRM relay “K1”
• Connect pin 5 to terminal strip “ZS/PS +”
• Connect pin 6 to terminal strip “ZS/PS”
• Connect pin 7 to LRM relay “K2”
Connect customer power supply; to do so:
• Connect customer-provided “24 V DC”
connection to LRM terminal strip “Power
”
• Connect customer-provided connection
“24 V DC” to LRM terminal “OUT 1”
• Connect customer-provided connec-
tion to LRM terminal strip “Ground
connection”
Pin
Code
Connection
Function
DB file
1
M
GND
Ground connection
KFGS_24V.db
Load (path file)
Monitoring
=> System
=> Update
=>
KFGS_24V.db
2
L+
12...24 VDC
Power supply
3
DK
Resetting a possible fault signal and
simultaneously triggering an interim
lubrication
4
SL2
K1, pin A1
Signal/fault
5
+
PS
Pressure switch
(pump-internal)
6
Signal
PS
Pressure switch
(pump-internal)
7
SL1
K2, pin A1
Pump switch on signal