5. Assembly
- 29 -
951-181-022-EN
Version 03
ATTENTION
C
heck the fuse protection of the electrical
circuit. Use only fuses with the prescribed
current intensity.
ATTENTION
Communication between the SKF
Lubrica-
tion Remote Monitor and the customer’s
system takes place according to customer
specifications and programming.
The system manufacturer is therefore
liable for proper connection of the SKF
Lubrication Remote Monitors and its
programming.
The SKF Lubrication Remote Monitor can be
used for all LRM2-approved pump versions.
Depending on the SKF pump version, the
24 VDC Monitor is supplied by the pump’s
power supply or the customer-supplied
power supply.
The LRM2 is adapted between pump-sup-
plied and customer-supplied power supply
using an adapter cable set.
The adapter cable set consists of one or two
cables supplied loose: one power supply
cable and one signal transmission cable. The
cable sets differ primarily in:
o Pump version, e.g., P203 or KFGS
o Pump voltage 24 VDC/110/230 VAC
Pin assignment:
o Fill level monitoring
o Fault notification signal
o Interim lubrication
These cables are equipped on the pump
side with adapter plugs/adapter sockets and
only with flexible cable leads to the LRM2.
The flexible cable leads are connected to the
LRM2 according to the terminal diagram of
the respective pumps; see Chapters 5.8.5
to 5.8.7.
The clamping range of the cable clamps is
0.25-2.5 mm.
Consult Chapter 3, “Technical data,” for the
electrical characteristics of the SKF Lubrica-
tion Remote Monitor.
Below is a breakdown of the installation de-
scription by pump types.