6
EN
6. Assembly
- 39 -
951-180-087-EN
Version 01
•
Screw the pressure screw (
4
) into the
cable socket (
1
) and tighten securely.
• Check the cable/screw union to make sure
they are sealed properly.
• Unscrew the cable socket (
1
) from the
pulse generator (
2
) and push the housing
(
3
) out of the cable socket.
• Unscrew the pressure screw (
4
) with
clamping disk (
5
) and cable gland (
6
) from
the cable socket (
1
).
• Compare the clamping range of the cable
gland (
6
) with the diameter of the cable
that will be inserted by the customer; only
use a cable with an appropriate diameter.
• Pull the customer-provided cable through
the pressure screw (
4
), clamping disk (
5
),
cable gland (
6
), and cable socket (
1
)
Observe the maximum clamping limit for
the terminal clamps ("Technical data"
chapter).
• Connect the flexible cable leads to the hous-
ing (
3
) according to the connection diagram,
Figure 5, (terminals 1 / terminal 3).
• Carefully insert the housing (
3
) into the
cable socket (
1
).
6.3 Electrical connection of pulse generator 24-2583-2526
See Figure 7
Electrical connection of pulse generator 24-2583-2526, Fig. 7
1
2
3
4
5 / 6
Terminal 3
Terminal 2
Terminal 1
Signal position:
1