2019 / 07
5. Deliver
y, returns, and storage
5. Delivery, returns, and storage
5.1 Delivery
Packaging is standard commercial packaging according to the regu-
lations of the recipient’s country. After receipt of the shipment, it
must be inspected for damage and for completeness according to
the shipping documents. The packaging material must be preserved
until any discrepancies are resolved.
Safe handling must be ensured during (on-site) transport. Do not tilt
or drop the product.
5.2 Returns
)
See Figure 10
All parts must be cleaned and properly packed before return ship-
ment. The product must be protected from mechanical effects such
as impacts. There are no restrictions for land, air, or sea trans-
port. The following must be marked on the packaging of return
shipments:
5.3 Storage until initial use
The following conditions apply to storage:
○
If possible, keep in original SKF shipping package
○
In dry, low-dust rooms
○
No direct sun or
UV exposure
○
No corrosive substances at storage area
○
No vibrations
○
Protected against animals (e.g., insects, rodents).
○
Protect product against nearby sources of heat or cold.
At approx. 6-month intervals:
○
Check for corrosion; if there are signs of corrosion, reapply anti-
corrosive agents.
5.4 Special storage conditions for ATEX motors
○
Do not store pump unit on the fan cowl.
○
Be sure to inspect insulation resistance before commissioning
after extended storage.
○
If decommissioned, briefly switch on the pump unit every 3
months (to lubricate the motor shaft). Ensure that the pump does
not run dry in the process.
○
Gently apply suitable rustproofing oil to bare metal parts every 6
months.
○
Observe the operating instructions from the motor manufacturer,
Chapter 6, “Operation, repair, maintenance.”
Temperature range:
○
Minimum -15°C
M 40°C
Storage time of parts pre-filled with lubricant:
○
Maximum of 24 months
Permissible humidity:
○
Non-condensing (maximum 90% relative humidity)
Returns, storage, and disposal, Fig. 10
5.5 Transporting the gerotor pump unit
)
See Figures 11 to 12
The gerotor pump unit is generally transported by the machine/
system builder. Its requirements for transportation of the gerotor
pump unit and the associated safety instructions must therefore be
observed.
Further, the following descriptions and safety instructions must like-
wise be observed.
WARNING
Use the provided lifting lugs to transport, set up, and install
the gerotor pump unit.
The permissible load capacity of the lifting lugs, lifting
ropes, lifting chains, or lifting equipment (crane, forklift)
may not be below the total weight of the gerotor pump
unit, including its packaging.
See the chapter “Technical data” for the permissible
total weight of the gerotor pump unit.
Add 20% to deter-
mine the load capacity.