3. Overview
, functional description
3.4 Functional description of gerotor
pump units
)
See Figure 3
SKF gerotor pump units of product series 143 are used in circu-
lating-oil and total-loss lubrication systems in a flow rate range of
0.85 to 50 l/min.
The standard permissible ambient temperature is between 0 and
+40°C. Higher ambient temperatures are possible, though they lead
to a reduction in motor performance and thus the delivery rate. In
this case, the maximum permissible temperature of the pumped
medium must be reduced.
The permissible temperature of the pumped medium is between 0
and +60°C.
The gerotor pumps include a gasket set made of FKM (FPM).
SKF gerotor pump units feed lubricating and hydraulic oils from a
reservoir and into the pipe system of a centralized lubrication sys-
tem. In doing so, they increase the energy of the pumped medium
(pressure increase) to overcome flow resistance in the pipelines
(pressure loss), the components (filters, valves, distributors), and the
bearings and friction points.
SKF gerotor pump units of different types and performance ratings
are used depending on the type and size of the centralized lubrica-
tion system and the lubricant (see pump code or “Technical data”
chapter).
C
Nominal delivery
rate
1)
Back pressure, max.
Motor drive power
Permiss. operating viscosity
range
Frame size
Number of
poles
[l/min]
[bar]
[kW]
[mm²/s]
B03D
0.85
30
0.25
20–1000
71
4
D03E
1.7
30
0.37
20–1000
71
2
F02D
2.5
20
0.25
20–1000
71
4
F05F
2.5
50
0.55
20–1000
80
4
H02F
5.25
20
0.55
20–1000
80
4
H05J
5.25
50
1.1
20–1000
90
4
K02H
9
20
0.75
20–1000
80
4
K05K
9
50
1.5
20–1000
90
4
M02H
12.5
20
0.75
20–1000
80
4
M05L
12.5
50
2.2
20–1000
100
4
P02L
19
20
2.2
20–1000
100
4
R02M
30
20
3
20–1000
100
2
R03M
30
30
3
20–750
100
2
R03N
30
30
4
20–1000
112
2
T02M
40
20
3
20–750
100
2
T03N
40
30
4
20–1000
112
2
V02N
50
20
4
20–1000
112
2
V03N
50
30
4
20–750
112
2
V03P
50
30
5.5
20–1000
132
2
1) Nominal delivery rate at motor speed 1400/2800 rpm acc. to number of motor poles.
Code for pump design
3.3 Order example
143-21FD03E-RE+1GD
o Gerotor pump unit of product series 143
(
143)
o Motor in foot design
(
1
)
o FKM (FPM) gasket
(
F
)
o Nominal delivery rate 1.7 l/min, back pressure 30 bar,
motor 0.37 kW/output
(
D03E
)
o Terminal box on right
(
R
)
o ATEX,
IEC Ex
motor certification
(E)
o
Voltage code 230/400 V, 50 Hz; 265/460 V,
60 Hz (±10%)
(
+1GD
)