![sitrex QRX 12 Assembly, Use And Maintenance Download Page 24](http://html1.mh-extra.com/html/sitrex/qrx-12/qrx-12_assembly-use-and-maintenance_1285852024.webp)
22
STEP 20
- With reference to Fig. 4.17
carry out the operations in the following order:
1) Mount the fittings on the valve (14) as shown in the figure.
2) Attach the valve (14) to the bracket 11) with bolts (15).
3) Fasten the assembly obtained to the machine at holes (16) n the frame using bolts (13), nuts (9) wash-
ers (12) and split washers (10).
Pos. Qty. Description
1
6
WASHER 3/8" BONDED
2
2
REDUCTION MF 3/8”M-1/4”F
3
2
THREADED MALE EYE 1/4"
4
2
PERFORATED HOLLOW SCREW FITTING 1/4"
5
4
WASHER 1/4" BONDED
6
4
“T” FITTING 1/4" M-F. SWIVELING -
7
2
ELBOW FITTING 90° M-F 1/4" SWIVELING
8
4
REDUCTION NIPPLE 3/8" GAS - 1/4"
9
4
NUT M 8 (5/16") DIN 980
10
4
SPLIT WASHER ø 8.4 (ø5/16") DIN 127B
12
4
FLAT WASHER ø 8.4 (ø5/16") DIN 125A
13
4
BOLT M 8 X 30 (5/16"x1"11/64) DIN 931 8.8
14
1
FLOW DIVERTER, ELECTRIC 3/8"
15
2
BOLT M 6 X 50 (15/64"x2’’) DIN 912 8.8
4.17
Summary of Contents for QRX 12
Page 1: ...ASSEMBLY USE AND MAINTENANCE QRX 12 14 201600 ...