background image

 

 

   

 

 

Document NO.:RD-517-39-001 

 

   

Version: B    2017.02.14 

- 4 - 

NOTE: 

Dense  smoke  will  override  the  alarm  silence  and 

sound a continuous alarm. 

CAUTION:

  Before  using  the  alarm  silence  (hush),  identify 

the source of the smoke and be certain a safe condition exists. 

DANGER: 

If the alarm sounds, and it is not being tested, it 

means  the  unit  is  sensing  smoke, 

THE  SOUND  OF  THE 

ALARM  REQUIRES  YOUR  IMMEDIATE  ATTENTION  AND 

ACTION.     

Maintenance and Cleaning:

 

 

In  addition  to  weekly  testing,  cleaning  to  remove  dust,  dirt, 

and  debris  at  least  once  a  month  is  highly  recommended. 

Always turn off the power before cleaning. 

Use  a  vacuum  cleaner  with  the  soft  brush,  vacuum  all  sides 

and covers of the smoke alarm. Be sure all the vents are free 

of debris. Use a damp cloth to clean the alarm’s cover. 

This smoke alarm uses a 9 volt battery. A fresh battery should 

last for at least one year under normal operate conditions. 

This  alarm  has  a  low  battery  monitor  which  will  cause  the 

alarm to “chirp” and at the same time the red LED will flash 

approx every 32 seconds for a minimum of thirty days when 

the battery gets low.  Replace the battery as soon as possible 

when  this  condition  occurs.  Please  refer  to  “

REPLACE 

BATTERY”. 

 

IMPORTANT:

 Do not attempt to remove the cover to clean 

inside. This will affect warranty. 

Repair: 

Caution:  Do  not  attempt  to  repair  the  alarm.  It  will  affect 

your warranty. 

If  the  alarm  is  not  operating  properly,  and  is  still  under 

warranty, return it to the original place of purchase. Pack it in 

a  well-padded  carton,  and  ship  to  the  original  place  of 

purchase.    If the alarm is no longer under warranty, replace 

it immediately with a comparable alarm.

 

Trouble shooting: 

WARING:

 Do not disconnect power to silence an unwanted 

alarm. This will remove your protection. Fan the air or open a 

window to remove smoke or dust. 

Problem 

Cause and Remedy 

 

 

The  green  LED  does 

not  light  when  AC 

power is connected. 

1.  Check  that  the  AC  QUICK 

CONNECTOR is properly connect 

to the smoke alarm.   

2.  If  the  problem  still  exists,  please 

return to your retailer. 

3.  If  the  unit  is  out  of  warranty, 

please replace another new alarm.   

 

 

Smoke alarm does not 

sound  when  tested. 

NOTE: 

Push 

test 

button for at least five 

seconds while testing. 

1.  Ensure  that  the  battery  and         

the  AC  QUICK  CONNECTOR 

are properly connected. 

2. Clean smoke alarm. 

3.  If  there  are  still  failures  during 

warranty, you can return the alarm 

to your retailer. 

4.  If  the  unit  is  out  of  warranty

 

please replace another new alarm 

The 

alarm 

chirp 

occurs    every  about 

approx 32 seconds

at 

the  same  time  as  the 

red LED flash once 

 

1.

 

The  battery  is  in  low  battery 

status,  please  replace  battery,  and 

refer to “replace battery” section.   

Smoke  alarm  chirp 

occurs  every  approx 

32  seconds

alarm 

goes 

into 

fault 

mode

Out of Warranty 

1.  Clean  smoke  alarm.  Please  refer 

to 

the 

“maintenance 

and 

cleaning” section. 

2.  Replace  the  defective  smoke 

alarm if the problem still persists.   

Smoke  alarm  sounds 

unwanted 

alarms 

intermittently 

or 

when  residents  are 

cooking, 

taking 

showers, etc. 

1. Press test button to pause alarm. 

2.  Clean  smoke  alarm.  Please  refer 

to 

the 

“maintenance 

and 

cleaning” section. 

3. Move smoke alarm device to new 

location  further  from  the  cooking 

source or bathroom and press test 

button to verify operation. 

 

 

The  alarm  sound  is 

different  than  normal. 

It starts and stops. 

1.  Clean  smoke  alarm.  Please  refer 

to the “maintenance and cleaning” 

section. 

2.If  there  are  still  failures  during 

warranty,  you  can  return  to  your 

retailer. 

3.  If  the  unit  is  out  of  warranty

 

please replace another new alarm. 

Develop and Practice a Plan of Escape: 

 

Install and maintain fire extinguishers on every level of the 

home and in the basement and garage. Know how to use a 

fire extinguisher prior to an emergency. 

 

Make a floor plan indicating all doors and windows and at 

least  two  escape  routes  from  each  room.  Second  story 

windows may need a rope or chain ladder. 

 

Have  a  family  meeting  and  discuss  your  escape  plan, 

showing everyone what to do in case of fire. 

 

Determine  a  place  outside  your  home  where  you  all  can 

Summary of Contents for GS517

Page 1: ...he basement ceiling at the bottom of the stairwell Typical multi storey dwelling installation recommendations Install a minimum of one smoke alarm on each occupiable level of the home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end install a ...

Page 2: ...adequate insure to protect their lives and property In addition it is possible for the smoke alarm to fail at any time For this reason you must test the smoke alarm weekly and replace them every 10 years Battery Specification Voltage DC 9V Carbon Zinc battery Gold Peak 1604P Replace Battery 1 Replace the battery Remove the locking plug between bracket and bottom cover See Diagram 1 Diagram 1 Remov...

Page 3: ... your alarm may indicate a defective alarm NOTE WEEKLY TESTING IS REQUIRED LED indicators Illumination of the Green LED indicates that the alarm is receiving AC power This alarm is equipped with a red LED indicator with two modes of operation Red LED Flashing every 32 seconds indicates that the smoke alarm is operating properly RED LED Flashing when the Test button is pressed or the smoke alarm se...

Page 4: ...he AC QUICK CONNECTOR is properly connect to the smoke alarm 2 If the problem still exists please return to your retailer 3 If the unit is out of warranty please replace another new alarm Smoke alarm does not sound when tested NOTE Push test button for at least five seconds while testing 1 Ensure that the battery and the AC QUICK CONNECTOR are properly connected 2 Clean smoke alarm 3 If there are ...

Page 5: ... there 6 Call the fire department from your neighbor s home not from yours 7 Don t return to your home until the fire officials say that it is all right to do so 8 There are situations where a smoke alarm may not be effective to protect against fire as stated in the National Fire Alarm and Signaling Code NFPA 72 For instance a Smoking in bed b Leaving children home alone c Cleaning with flammable ...

Page 6: ...nimum protection install at least one alarm close to the bedrooms For additional protection see SINGLE FLOOR PLAN and MULTIPLE FLOOR PLAN in Diagram 7 Diagram 7 WARNING TEST YOUR SMOKE ALARM OPERATION AFTER MOBILE HOME HAS BEEN IN STORAGE BEFORE EACH TRIPAND AT LEAST ONCE A WEEK DURING USE Wiring Instructions The appropriate power source is 120 volt AC single phase When installing or removing the ...

Page 7: ...holes of the bracket with a pencil Bore two installation holes in the marked positions with a 3 16 5 mm drill bit Press the two plastic plugs into holes with hammer Refer to Diagram 10 Diagram 10 Pull the AC QUICK CONNECTOR through the center hole in the bracket Attach the bracket to the plastic plugs and tighten the screws into the plastic plugs refer to Diagram 11 installation sketch map Install...

Page 8: ... use and service for a period of 3 years from the date of purchase This warranty does not cover damage resulting from accident misuse or abuse or lack of reasonable care of the product In no case shall company be liable for any incidental or consequential damages for breach of this or any other warranty express or implied whatsoever The defective product can be mailed to the following address with...

Reviews: