Document NO.:RD-517-39-001 

 

   

Version: B    2017.02.14 

- 2 - 

detects smoke. 

7.

 

Smoke  alarm  may  not  alert  every  household  member 

every  time.  The  alarm  horn  is  loud  in  order  to  alert 

individuals  to  a  potential  danger.  However,  there  may  be 

some circumstances where a household member may not 

hear  the  alarm  (i.e.  outdoor  or  indoor  noise,  sound 

sleepers, drug or alcohol usage, the hard of hearing, etc.). 

If  you  suspect  that  this  smoke  alarm  may  not  alert  a 

household  member,  install  and  maintain  specialty  smoke 

alarms.  Household  member  must  hear  the  alarm’s 

warning sound and quickly respond to it to reduce the risk 

of injury, or death that may result from fire, if a household 

member  is  hard  of  hearing,  install  special  smoke  alarms 

with lights or vibrating devices to alert occupants. 

8.

 

Smoke  alarms  can  only  sound  their  alarms  when  they 

detect  smoke  or  detect  combustion  particles  in  the  air. 

They do not sense heat, flame, or gas. This smoke alarm 

is  designed  to  give  audible  warning  of  a  developing  fire. 

However,  many  fires  are  fast  -  burning,  explosive,  or 

intentional,  and  others  are  caused  by  carelessness  or 

safety  hazards.  In  such  circumstances,  Smoke  may  not 

reach  the  alarm 

QUICKLY  ENOUGH 

to  ensure  safe 

escape. Therefore the installation of smoke alarms is not a 

substitute for practicing fire safety in the home.   

9.

 

Smoke  alarms  have  limitations.  This  smoke  alarm  is  not 

foolproof and is not warranted to protect lives or property 

from fire. Smoke alarms are not a substitute for insurance. 

Homeowners  and  renters  should  have  adequate  insure  to 

protect their lives and property. In addition, it is possible 

for  the  smoke  alarm  to  fail  at  any  time.  For  this  reason, 

you  must  test  the  smoke  alarm  weekly  and  replace  them 

every 10 years. 

Battery Specification:

 

 

Voltage: DC 9V (Carbon Zinc battery) 

Gold Peak: 1604P 

Replace Battery: 

1: Replace the battery: 

 

Remove  the  locking  plug  between  bracket  and  bottom 

cover. (See Diagram 1)

 

 

Diagram 1 

 

Remove the alarm body from the bracket. 

 

Squeeze  the  locking  arms  on  the  sides  of  the  AC  Quick 

connector  while  pulling  the  connector  away  from  the 

bottom of the alarm. 

 

 

After  alarm  has  been  removed,  you  can  open  the  battery 

cover and replace with new battery. (See Diagram 2)

 

 

Diagram 2 

Warning: AC power should be turned off at this stage. 

2: After you replaced the battery: 

 

Close the battery cover,   

 

Plug the AC QUICK CONNECTOR into the back of the 

alarm, making sure that the locks on the connector snap 

into place.   

 

Fit  the  alarm  body  on  bracket  and  turn  the  alarm  body 

clockwise (See Diagram 3).     

 

Diagram 3 

 

Insert  locking  plug  into  the  gap  between  bracket  and 

bottom cover (See Diagram 4). 

 

Diagram 4 

3:  Turn  on  the  AC  power,  in  the  meantime,  the  green  LED 

lights  up.  Then  test  smoke  alarm  using  test  button,  the 

sound  pattern  is  3  short  beeps-pause  1.5  seconds,  cycle 

this pattern continues until release the test button. 

Then unit will goes into hush mode of 8 minutes. During this 

period, the RED LED will flash once every 8 seconds. It will 

go  to  normal  operation  status  and  flash  once  every  32 

seconds after 8 minutes. Test the smoke alarm by pushing the 

test  button,  if  the  alarm  signal  does  not  sound,  this  is  an 

indication  that  the  smoke  alarm  is  faulty  or  improperly 

installed. Refer to the “trouble shooting” section for help.

   

Summary of Contents for GS517

Page 1: ...he basement ceiling at the bottom of the stairwell Typical multi storey dwelling installation recommendations Install a minimum of one smoke alarm on each occupiable level of the home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end install a ...

Page 2: ...adequate insure to protect their lives and property In addition it is possible for the smoke alarm to fail at any time For this reason you must test the smoke alarm weekly and replace them every 10 years Battery Specification Voltage DC 9V Carbon Zinc battery Gold Peak 1604P Replace Battery 1 Replace the battery Remove the locking plug between bracket and bottom cover See Diagram 1 Diagram 1 Remov...

Page 3: ... your alarm may indicate a defective alarm NOTE WEEKLY TESTING IS REQUIRED LED indicators Illumination of the Green LED indicates that the alarm is receiving AC power This alarm is equipped with a red LED indicator with two modes of operation Red LED Flashing every 32 seconds indicates that the smoke alarm is operating properly RED LED Flashing when the Test button is pressed or the smoke alarm se...

Page 4: ...he AC QUICK CONNECTOR is properly connect to the smoke alarm 2 If the problem still exists please return to your retailer 3 If the unit is out of warranty please replace another new alarm Smoke alarm does not sound when tested NOTE Push test button for at least five seconds while testing 1 Ensure that the battery and the AC QUICK CONNECTOR are properly connected 2 Clean smoke alarm 3 If there are ...

Page 5: ... there 6 Call the fire department from your neighbor s home not from yours 7 Don t return to your home until the fire officials say that it is all right to do so 8 There are situations where a smoke alarm may not be effective to protect against fire as stated in the National Fire Alarm and Signaling Code NFPA 72 For instance a Smoking in bed b Leaving children home alone c Cleaning with flammable ...

Page 6: ...nimum protection install at least one alarm close to the bedrooms For additional protection see SINGLE FLOOR PLAN and MULTIPLE FLOOR PLAN in Diagram 7 Diagram 7 WARNING TEST YOUR SMOKE ALARM OPERATION AFTER MOBILE HOME HAS BEEN IN STORAGE BEFORE EACH TRIPAND AT LEAST ONCE A WEEK DURING USE Wiring Instructions The appropriate power source is 120 volt AC single phase When installing or removing the ...

Page 7: ...holes of the bracket with a pencil Bore two installation holes in the marked positions with a 3 16 5 mm drill bit Press the two plastic plugs into holes with hammer Refer to Diagram 10 Diagram 10 Pull the AC QUICK CONNECTOR through the center hole in the bracket Attach the bracket to the plastic plugs and tighten the screws into the plastic plugs refer to Diagram 11 installation sketch map Install...

Page 8: ... use and service for a period of 3 years from the date of purchase This warranty does not cover damage resulting from accident misuse or abuse or lack of reasonable care of the product In no case shall company be liable for any incidental or consequential damages for breach of this or any other warranty express or implied whatsoever The defective product can be mailed to the following address with...

Reviews: