background image

User’s Manual

TABLE OF CONTENTS

1. 

BASIC FUNCTIONAL DESCRIPTION ................................................................................2

2. SPECIFICATIONS .......................................................................................................................... 3
3. CONTROLLER .................................................................................................................................4

3.1.   TECHNICAL CHARACTERISTICS .............................................................................4
3.2.   INSTALLATION ...................................................................................................................4
3.3.   CONNECTIONS .................................................................................................................4
3.4.   CONTROL AND MANAGEMENT OF THE CONTROLLER ......................6

4. 

LINKING THE CONTROLLER TO THE MOBILE APP..............................................7

5. 

QUICK GUIDE TO CONFIGURING PROGRAMMING.............................................8

6. 

MOBILE APP .................................................................................................................................10

6.1.   AVAILABLE PROGRAMS ............................................................................................10
6.2.   UNAVAILABLE CONTROLLERS (NO CONNECTION) .............................10
6.3.   CONFIGURING THE MOBILE APP ...................................................................... 11
6.4.   MENU ..................................................................................................................................... 11
6.5.   START ..................................................................................................................................... 12
6.6.   CONFIGURING THE CONTROLLER...................................................................14
6.7.   CONFIGURING THE INSTALLER .......................................................................... 17
6.8.   SECTORS .............................................................................................................................18
6.9.   CONFIGURING A SECTOR ......................................................................................20
6.10.   PROGRAMS ..................................................................................................................... 21
6.11.   CONFIGURING A PROGRAM ...............................................................................24
6.12.   STATUS OF THE CONTROLLER ......................................................................... 26
6.13.   CONTROLLER MANUAL AND MORE INFORMATION ........................ 26

7. 

MANUAL BUTTON .................................................................................................................... 27

8. 

TROUBLESHOOTING GUIDE AND Q&A ....................................................................28

Version 1

AGRÓNIC

SMART

Summary of Contents for Agronic Smart

Page 1: ...IGURING PROGRAMMING 8 6 MOBILE APP 10 6 1 AVAILABLE PROGRAMS 10 6 2 UNAVAILABLE CONTROLLERS NO CONNECTION 10 6 3 CONFIGURING THE MOBILE APP 11 6 4 MENU 11 6 5 START 12 6 6 CONFIGURING THE CONTROLLER 14 6 7 CONFIGURING THE INSTALLER 17 6 8 SECTORS 18 6 9 CONFIGURING A SECTOR 20 6 10 PROGRAMS 21 6 11 CONFIGURING A PROGRAM 24 6 12 STATUS OF THE CONTROLLER 26 6 13 CONTROLLER MANUAL AND MORE INFORMATIO...

Page 2: ... fertilizer management and an alternating sector sequence in a single program The controller has 10 outputs which are managed based on the established configuration 10 sectors 9 sectors 1 general 9 sectors 1 fertilizer Plus version 8 sectors 1 general 1 fertilizer Plus version It also has 2 digital inputs which can be used as digital sensors to establish different determining factors for starting ...

Page 3: ... or by frequency of days Start based on schedule manually or by digital input Plus version Alternating sequence Each time the program starts it will do so in a different sector in accordance with the defined sequence Fertilizer Use of fertilizer and specification of fertilization time for each sector in the program sequence Manual actions accessible from the Agrónic Smart app Controller Set the cl...

Page 4: ...oller may be installed on a wall or on the upper part of a pole It includes a stainless support that facilitates mounting 3 2 INSTALLATION Temperature 10 C to 60 C Humidity 95 Altitude 2000 m Pollution Degree II IP 67 3 3 CONNECTIONS The controller is delivered with a 15 wire hose to facilitate the connections In order to ensure that the cables on the module hose are watertight the use of watertig...

Page 5: ...Common stop CP on diode box Red blue 12 Common start CM on diode box White green 13 Input 1 Brown green 14 Input 2 White yellow 15 Common inputs The cables on the different hoses are identified by colour and number Connect them using the following table based on their functionality For 3 wire models a diode box is required See assembly diagram on the next page You may use 3M Scotchlok connectors w...

Page 6: ...he mobile device must be located near the controller in order to be able to communicate with it The typical coverage that it offers ranges from 200m if there is a direct line of sight to a few metres if there are many objects between the controller and the mobile device The app can operate and connect to the controller even without an Internet connection 3 4 CONTROL AND MANAGEMENT OF THE CONTROLLE...

Page 7: ... to the on position On the mobile device open Google Play or the App Store and download the Agrónic Smart app 1 2 Activate Bluetooth on the device The first time a mobile device connects to the controller it will ask for a PIN code which is provided along with the controller Open the app To help you create irrigation programming the next section contains a quick guide to configuring it 3 5 4 6 ...

Page 8: ...r which may be accessed through the icon at the upper right In each sector we can edit the name and add a photo to better identify it Once the controller has been configured we can personalise the sectors in which we plan to work The next step is to create an irrigation program 1 3 2 4 ...

Page 9: ...the sector If you would like to work with grouped sectors or an alternating sequence or add a manual factor please see the Configuring programs section Select the type of start if we want it to irrigate on specific days or by frequency and the daily number of hours of irrigation And this is the basic configuration you ll need to start irrigating with the Agrónic Smart 5 7 6 8 ...

Page 10: ...the controller in your search results another mobile device may be connected Once the controller has been linked to the app the Agrónic Smart programming can be accessed even if it is unavailable no connection and controller and program values can be modified The edited values will be highlighted in yellow These edited values will not be sent until the controller is reconnected to the app Once the...

Page 11: ... selected screen is in yellow Manual and More information Use this section to view the manual and references to the versions of the controller and the app Sectors List of the sectors configured in the controller View the status and manual actions of a particular sector Home Principal screen which displays a summary of the status of the controller Programs List of the programs configured in the con...

Page 12: ... The home page on the app displays a summary of the controller The background colour indicates the status of the controller Yellow means it s connected Grey means it s disconnected 6 5 HOME RSSI level of the controller Information on the programs that will irrigate today Information on sectors in manual stop start status Information on the status of the general output whether fertilizer is used an...

Page 13: ...at this time Controller is connected Irrigation is programmed for today Controller is connected Manual status of the controller is stopped Controller is connected No Internet access Irrigation is programmed for today Controller is not connected Controller is connected Manual status of the controller is out of service ...

Page 14: ...stablished Name Name to be given to the controller General Active Yes Inactive No Start stop temporization The delay or advance of the general output in relation to the sectors is specified in seconds start temporization stop temporization Start temporization amount of time activation of the general output is delayed on beginning irrigation from 0 to 999 Stop temporization amount of time stopping ...

Page 15: ...rts and on completion it will keep the valve open for the programmed number of seconds Where the value is negative it will delay opening for the programmed number of seconds and close immediately on completion As an exception a sector may be the final one in an irrigation sequence and the stop temporization for the general output general output water hammer may be applied Fertilizer Available for ...

Page 16: ...and conditional stops this is the time that elapses between the activation of the corresponding input and the time at which the temporary or conditional stop takes place Format Two available time formats hours minutes hh mm or minutes seconds mm ss Sector meter Coming soon If it has a meter you must select the input where it will operate Input 1 Input 2 Date and time of controller Display shows th...

Page 17: ...ou can set a different number It must always have 6 digits Activation of Plus version By entering the applicable code this information is provided by Progrés under contract you can activate the Plus version which adds extra functionalities to the controller Alternating sequence Each time a program starts it will do so in a different sector in accordance with the sequence defined in the program Use...

Page 18: ...ll occupy 2 sectors as a result only 8 sectors may be configured Indication that the sector is irrigating Indication that the sector is irrigating in manual mode Image assigned to the sector Sector does not have an image assigned Indication that the sector is stopped in manual mode Indication that the sector is not irrigating Output assigned to active fertilizer Output assigned to active general o...

Page 19: ...rams assigned to the sector Manual actions The background colour indicates the status of the sector Blue means it s irrigating Dark blue means it s not irrigating Purple line when there is a manual action Name of the sector You can change the state of the sector with manual actions Start manual start irrigation manually if you ahve an associated pump this will be activated Stop manual stop the sec...

Page 20: ...ios on the view screen for the sector Sector not being irrigated next irrigation start date is 14 08 You can assign a name and image to each sector by selecting the button at the top right of the screen for the sector to be configured 6 9 CONFIGURING A SECTOR Cancel edits Save edits Select to upload or edit the image Name of the sector maximum of 14 characters Images are not transferred between mo...

Page 21: ...ave up to 10 sectors The 5 available programs with irrigation information and associated sectors are listed on the program screen in the app The purple line indicates that the program is performing a manual action The transparent box indicates that the program is out of service Undefined program Total duration of program The blue line indicates that the sector is being irrigated Grouped sectors Na...

Page 22: ... Duration of sector and fertilizer and remaining time Manual actions Type of start schedule or assigned input You can change the status of the program with manual actions Start starts the program manually even if it is outside the active hours and active period Parar stops the program in progress and will continue with the established schedule Suspend suspends the program for the hours specified T...

Page 23: ...ferent scenarios on the program screen Program irrigating initiated by a manual action Program paused for several hours Program out of service Program delayed due to a sector in manual stop status A purple line indicates that the sector is in manual status The background colour indicates the status of the controller Blue means it s irrigating Dark blue means it s not irrigating Purple line when th...

Page 24: ...rigation will occur Frequency of days you ll need to specify how frequently irrigation will occur Every x days 1 irrigates each day 2 irrigates every other day 3 irrigates one day but not the next two Start in x days You can modify the number of days remaining until the next irrigation Irrigation times if the start is pursuant to a schedule Up to 5 different start times may be entered Irrigation s...

Page 25: ...awn 3 Plants Third start Lawn 2 Lawn 3 Plants Lawn 1 Fourth start Lawn 3 Plants Lawn 1 Lawn 2 Fifth start Plants Lawn 1 Lawn 2 Lawn 3 Manual factor Modifies the irrigation time for this program pursuant to the specified A positive value means that the irrigation time for this program will increase by this percentage A negative value means that the irrigation time for this program will decrease by ...

Page 26: ...igation in process delaying it Any new irrigation will also be delayed Start Any irrigation that was delayed will continue from where it left off Out of service Cancels all irrigation in progress Does not permit entry of any new irrigation Use this screen to access the controller manual information regarding the version and manufacturer and links to legal information ...

Page 27: ...nd to activate stop output given through n number of pulses n short pulses 3 pulse Manual command to activate stop program given through n number of pulses 3 pulse 3 pulse Enter or exit STOP 3 pulse 8 short pulses 3 pulse The access PIN will reset to its default value initial value 3 pulse 1 short pulse 3 pulse TEST ON Manual start stop command for all outputs sequentially lasting 3 minutes or unt...

Page 28: ...et all requested permissions to yes The app is not connecting to the Agrónic Smart PIN code error Make sure the PIN code you ve entered is correct 6 digits If the PIN has been modified to less than 6 digits the first digits should be ZEROS Ex PIN 123 ACTUAL PIN 000123 Bluetooth error In the event the PIN entered is correct Close the application Go to the list of associated Bluetooth devices Unlink...

Page 29: ...s or select don t send to return to the previous programming Do the temporary stop and conditional stop inputs affect the sectors The stop inputs only affect the programs Can I name the inputs You can not name the inputs How can I reactive a program that has been suspended for a certain amount of time To reactivate the program select the pause button put the time to 00 00 and send Can I put a long...

Page 30: ...PERSONAL NOTES ...

Page 31: ...PERSONAL NOTES ...

Page 32: ...R 2342 Polígon Industrial C de la Coma 2 25243 El Palau d Anglesola Lleida España Tel 973 32 04 29 info progres es www progres es Sistemes Electrònics Progrés S A ...