7. Manual button
The Agrónic Smart controller has an internal button that allows you to carry out several basic
functions or check the status of the controller:
• Short pulses (< 0.5”): Indicates the status of the controller through the LED light on the
controller:
‒ LED 1 ON for 2”. Controller functioning properly
‒ LED 2 ON for 2”. Low battery (< 2.5V)
• 3” pulse + “n” short pulses. Manual command to activate/stop output given through “n”
number of pulses.
• “n” short 3” pulse. Manual command to activate/stop program given through “n”
number of pulses.
• 3” pulse + 3” pulse. Enter or exit STOP.
• 3” pulse + 8 short 3” pulse. The access PIN will reset to its default value: initial value.
• 3” pulse + 1 short pulse + 3” pulse. TEST ON → Manual start/stop command for all outputs
sequentially, lasting 3 minutes or until the “TEST OFF” command is given.
• 3” pulse + 2 short 3” pulse. TEST OFF → Manual stop command for all outputs. All
outputs will be set to automatic.
Button
OFF > ON
LED 1 LED 2
Summary of Contents for Agronic Smart