background image

             Intervention                                       Carried out by

Replacement of the dust bag                                             User

Cleaning of the filetr cartidge                                             User

Check the air exhaust obstruction                                Assistanzce service

- ATTENTION -

NEVER USE THE CENTRAL UNIT

WITHOUT THE DUST BAG

Frequency

Dust bag full

Each bag replacement

Once a year

12

6 - MAINTENANCE

- ATTENTION -

ALWAYS UNPLUG THE POWER SUPPLY CABLE FROM

THE POWER SUPPLY SOCKET AND ALWAYS WEAR

PROTECTION GLOVES AND GOGGLES BEFORE

CARRYING OUT ANY TECHNICAL OR

MAINTENANCE OPERATION

• 

6.1

Programmed maintenance

According  to  the  accumulated  operating  time  of  the  central  vacuum  system,  it  is  necessary  to  carry  out
maintenance operations in order to keep the central unit always well performing and to avoid serious mechanical
problems. It is suggested to carry out the following maintenance operations:

The casing of the suction unit needs periodically cleaning. Use a smooth and damp cloth with some neutral
soap.

Attention: Be sure to use only water or water with neutral soap. Alcohol or other solvents may damage
the unit. Wait until the unit is perfectly dry prior to start it.

Open and remove the lower cover

1

• 

6.2   Replacement of the dust bag

Wolly2 12/12-V01

E

n

g

li

s

h

3

2

1

Summary of Contents for 8201.0

Page 1: ......

Page 2: ...4 3 Installation spaces 9 4 4 Installation applications 9 4 5 Installation with direct frontal air discharge without pipes net 9 4 6 Installtion with carried air discharge with pipes net 9 4 7 Electri...

Page 3: ...odel Item code Serial number Year of manufacturing Purchase date Purchase place Detailed information on the arisen troubles or on the kind of information required All the technical data related to the...

Page 4: ...or replacing cleaning the filter Use only original spare parts Never use the vacuum unit to remove textile stuff big size bits and pieces of any material burning coals or ashes Never vacuum liquids Do...

Page 5: ...until you put it into service in order to keep the central unit in perfect conditions ATTENTION The packing materials delivered with the central unit are inert solid wastes that must be disposed as p...

Page 6: ...accessories English 5 Wolly2 12 12 V01 M a n u a le T e c n ic o p e r c e n tr a l i a s p i r a n ti c i v i l i N 1 x N 1 x N 1 x N 1 x N 1 x N 2 x N 1 x N 1 x N 1 x N 1 x N 1 x N 1 x N 1 x N 2 x...

Page 7: ...different use is strictly forbidden The manufacturer must approve by means of written authorization any alteration or modification of the suction unit to remove a specific material Any use different f...

Page 8: ...ns Electric box Upper door Upper door Lock Safety filter Dust collection bag Lower door Lower door Centering pins Dust entry Clamps for wall fixing Air ventilation Safety thermic feeler Motor Motor so...

Page 9: ...echnical features Absorption 1 230 kW 1 3 A 5 6 V dc 12 m3 h 234 12 YES kg 8 0 Technical features N users Max Power supply Frequency Motor power Inlet power supply Max air volume Dust container capaci...

Page 10: ...he outside installations it s better to choose some areas that are less exposed to sunlight Chose a space far from heat sources burners or radiators Provide spaces for the unit air flow entry and exit...

Page 11: ...Do not connect the machine to a power line with excessive tension rush ideal tension local voltage 10 Power the low voltage inlet signal with safe very low tension It is requested during the unit inst...

Page 12: ...hose from the suction inlet The central unit will stop automatically NOTE allow the central vacuum unit a few minutes to stop Wolly2 12 12 V01 11 English 5 1 Starting the central vacuum unit 5 HOW TO...

Page 13: ...med maintenance According to the accumulated operating time of the central vacuum system it is necessary to carry out maintenance operations in order to keep the central unit always well performing an...

Page 14: ...so to fit the bag membrane into its slot English 13 Wolly2 12 12 V01 Reassemble the cover verifying that the two tooths fit in to two seats of the unit Verify that the bag doesn t go outside 4 3 Gentl...

Page 15: ...e dust bag from the aspiration feed Unscrew the locking handle Replace the filter cartridge Reassemble dust bag and cover 14 6 3 Replacement of the filter cartidge Open the lower cover Clean the passa...

Page 16: ...ntenance or servicing not mentioned and therefore not allowed in the user manual Only qualified providers of the technical assistance service can carry out any maintenance or repair operations The gua...

Page 17: ...l resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service the shop where you purchased the product your loca...

Page 18: ......

Reviews: