Wolly2 12/12-V01

• 

3.2

Allowed and improper use

The central vacuum unit has been designed to remove the dust, small-size solid bits and pieces and dry materials.
It is forbidden to use the vacuum system to remove textile stuff, big-size bits and pieces, burning and hot
materials.
NEVER vacuum liquids!
Do not vacuum organic material that may ferment.
It is strictly forbidden to remove highly explosive materials (gun powder) or inert materials, which can trigger
dangerous  chemical  reactions  if  removed  separately  and  then  mixed  up  in  the  dust  container.
It is strictly forbidden to use the central suction unit in explosion hazard places or in places where temperature,
pressure and moisture are out-of-range.

Any different use is strictly forbidden.
The manufacturer must approve, by means of written authorization, any alteration
or  modification  of  the  suction  unit  to  remove  a  specific  material.
Any use different from the original is to be considered improper and health risk for
the user and damage to the suction unit cannot be excluded.

3 - DESCRIPTION OF THE CENTRAL VACUUM UNIT

• 

3.1

Operating principles

The central suction system, suitable for any kind of residential building (house, office, hotels, service building)
consists of a of PVC pipes network, under the floors, inside the walls or the false ceiling, spreading in the various
rooms and with the suction inlets placed at the end of each sector.
The central vacuum unit, located in utility rooms, garages or similar places, is connected to the piping network.
The user starts the central vacuum unit by simply inserting the fitting of the suction hose into the suction pipe
inlet.

Summary of Contents for 8201.0

Page 1: ......

Page 2: ...4 3 Installation spaces 9 4 4 Installation applications 9 4 5 Installation with direct frontal air discharge without pipes net 9 4 6 Installtion with carried air discharge with pipes net 9 4 7 Electri...

Page 3: ...odel Item code Serial number Year of manufacturing Purchase date Purchase place Detailed information on the arisen troubles or on the kind of information required All the technical data related to the...

Page 4: ...or replacing cleaning the filter Use only original spare parts Never use the vacuum unit to remove textile stuff big size bits and pieces of any material burning coals or ashes Never vacuum liquids Do...

Page 5: ...until you put it into service in order to keep the central unit in perfect conditions ATTENTION The packing materials delivered with the central unit are inert solid wastes that must be disposed as p...

Page 6: ...accessories English 5 Wolly2 12 12 V01 M a n u a le T e c n ic o p e r c e n tr a l i a s p i r a n ti c i v i l i N 1 x N 1 x N 1 x N 1 x N 1 x N 2 x N 1 x N 1 x N 1 x N 1 x N 1 x N 1 x N 1 x N 2 x...

Page 7: ...different use is strictly forbidden The manufacturer must approve by means of written authorization any alteration or modification of the suction unit to remove a specific material Any use different f...

Page 8: ...ns Electric box Upper door Upper door Lock Safety filter Dust collection bag Lower door Lower door Centering pins Dust entry Clamps for wall fixing Air ventilation Safety thermic feeler Motor Motor so...

Page 9: ...echnical features Absorption 1 230 kW 1 3 A 5 6 V dc 12 m3 h 234 12 YES kg 8 0 Technical features N users Max Power supply Frequency Motor power Inlet power supply Max air volume Dust container capaci...

Page 10: ...he outside installations it s better to choose some areas that are less exposed to sunlight Chose a space far from heat sources burners or radiators Provide spaces for the unit air flow entry and exit...

Page 11: ...Do not connect the machine to a power line with excessive tension rush ideal tension local voltage 10 Power the low voltage inlet signal with safe very low tension It is requested during the unit inst...

Page 12: ...hose from the suction inlet The central unit will stop automatically NOTE allow the central vacuum unit a few minutes to stop Wolly2 12 12 V01 11 English 5 1 Starting the central vacuum unit 5 HOW TO...

Page 13: ...med maintenance According to the accumulated operating time of the central vacuum system it is necessary to carry out maintenance operations in order to keep the central unit always well performing an...

Page 14: ...so to fit the bag membrane into its slot English 13 Wolly2 12 12 V01 Reassemble the cover verifying that the two tooths fit in to two seats of the unit Verify that the bag doesn t go outside 4 3 Gentl...

Page 15: ...e dust bag from the aspiration feed Unscrew the locking handle Replace the filter cartridge Reassemble dust bag and cover 14 6 3 Replacement of the filter cartidge Open the lower cover Clean the passa...

Page 16: ...ntenance or servicing not mentioned and therefore not allowed in the user manual Only qualified providers of the technical assistance service can carry out any maintenance or repair operations The gua...

Page 17: ...l resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service the shop where you purchased the product your loca...

Page 18: ......