- high quality furniture fittings
4
The lock automatically recognizes the programming card and the data carrier included in the lock. However, programming
can be changed at any time, as described in the following.
Programming of the card
Press the programming key
(1)
of the lock for three seconds until you hear a long acoustic signal followed by a ticking lasting for
approx. 7 seconds. During the ticking signal hold the programming card
(8)
to the identification zone
(3)
until you hear an acoustic
signal of recognition. Now the card is programmed.
Programming of the data carrier
Hold the programming card
(8)
once to the identification zone
(3)
. A ticking lasting for 7 seconds is to be heard. During the ticking
hold the data carrier
(7)
to the identification zone
(3)
for read-in until you hear an acoustic signal of recognition. Now the data
carrier is programmed.
Control the data carrier as to its functioning
Hold the data carrier
(7)
to the identification zone
(3)
until you hear an acoustic recognition signal and until the spring advances.
Hold the data carrier
(7)
once again tho the identification zone
(3)
until you hear an acoustic recognition signal and the opening
interval is started.
Delete individual programmed data carriers
Hold the programming card
(8)
once to the identification zone
(3)
until you hear a ticking lasting for approx. 7 seconds. Hold the data
carrier
(7)
for deletion to the identification area during the ticking until hear a recognition signal. Now the data carrier is deleted.
Delete all programmed data carriers
Hold the programming card
(8)
to the identification zone
(3)
until you hear four short acoustic signals followed by a long recognition
signal. Now all the programmed data carrier are deleted und the spring has returned into opening position.
Activate or deactivate the acoustic signal
Push the programming key
(1)
for one second.
All settings, for which the programming key (1) is not needed, can be made with the lock already mounted. The electro-
nics
of the lock is able to read the data carrier and the programming card even through materials of up to 20 mm thickness.
Warning:
The correct functioning can only be guaranteed if the lock is mounted on non-conducting materials (wood, synthetic
material) with a max. thickness of 20 mm. In case of a higher thickness, with metal doors or doors with a metal application, an
antenna has to be installed.
Programming instruction
1
3
1 programming key
3 identification zone
5 bolting holes
7 data carrier
2 lateral part
4 spring
6 battery chamber
8 programming card
2
5
5
5
6
4
Battery removal
Open the battery chamber
(6)
, remove the used battery and, in order to avoid a malfunction, wait approx.
30 seconds
before
inserting the new battery. Take care of the polarity
(+/-)
as indicated at the bottom of the battery chamber and on the battery.
The integrated lithium cell 3V has a useful life of 20,000 openings. Before the cell is used, an acoustic signal indicates
that the cell should be replaced. If this signal goes unheard, the lock is opened with the residual power and remains
opened until the cell is replaced.
8
7