1.) Mechanical installation

Increase the GENIUS lock recess at the top near the power cable by approx. 15 mm.

Install cylinder in accordance with DIN 18252.

CAUTION: Metal filings at the connecting terminals of the GENIUS System may damage the internal electronics.

                   GENIUS systems with the convenience feature (CA/CB only) do not have openings for

                   door-handle rose bolts.

3.) Operating mode:

Switch position up = day mode

Switch position down = night mode

4.) Detection of open/closed door:

Install the sensor centrally (± 1 mm) to the reed sensor.

Max. distance 4 mm (± 3 mm)

2.) Connections GENIUS type B

Position State

Notes

The lock is fully locked and the 

door is closed.

• 

For use in combination with alarm systems.

 ›    Terminal 7 is connected to negative (--) ground.

The door is closed

• 

For use in combination with doorman monitoring.

 ›    Terminal 7 is connected to negative (--) ground.

The latch is pulled into the cylin-

der operated lock

• 

For use in combination with a revolving door motor.

 ›    Terminal 7 is connected to negative (--) ground.

A connected alarm system can be 

activated or deactivated

• 

Control with 2-channel infra-red access key*

• 

In order to keep the alarm system activated in the event of a po-

wer failure, the terminal is connected to negative/ground when 

the alarm is deactivated.

›     Alarm deactivated = terminal 7 = negative -- relay on
›     Alarm activated = terminal 7 = high resistance -- relay off

• 

The relay break contact must be used to switch on the alarm 

system.

5.) Rotary switch (optional signal outputs)

Terminal 7; open collector; max. load 20 mA; isolated due to coupling relay 24V (KFV accessory).

Fig. 1

Fig. 2

Connec-

tions

Function

A, B, C, D

B, C, D, 2

Connection for the IR sensor which carries

IR signals to the GENIUS door lock switch

Connection of KFV finger scanner

0, 1

Mode switch

Day/night mode

2, 3

Operating voltage 24V DC

Terminal 2 = + positive

Terminal 3 = – negative

4

External unlocking signal.

If +24 VDC is supplied to this terminal for 

1 sec., then an opening cycle is perfor-

med in both operating modes

7

Lock status indication.

The desired state is selected by the 

rotary switch (optional signal output max. 

20mA)

* See GENIUS operating instructions for details on controls

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

H47.ELEKKFV0005EN/2013-08/0

For fast access

Quick Reference

GENIUS type B

EN