Sublimation-program (03)

 

 

Press button 

 

 

The display shows up 

03, 

followed by the audible signal and blinking   

 

On the display the preset parameters appear: 

200°C

 and

 60 

seconds

 

The 

operator 

may 

change 

the 

preset 

parameters 

with 

buttons 

„+“ 

and 

„-„

.  

The 

modified 

 

parameters 

may 

be 

saved 

directly 

by 

pressing 

button 

S

 

 

and 

may  

always be recalled and altered again.  

The 

preset 

temperature 

may 

be 

modified 

in 

each 

program 

(01…02…03) 

plus 

or  

minus 20 °C.  For the standard program however, temperatures between 0°C and 250° may be adjusted.  

Display signals 

In  case  of  failures,  the  new  control  board 

TS2  3P

  gives  different  signals  in  order  to  

discover and resolve the problem immediately.  

 

If   

111

  appears  on  the  display  and  the  light  blinks,  followed  by  an  acoustic  

signal, the temperature sensor is defect or not connected with the control board.

 

 

 

 

 

If   

000

  appears  on  the  display  and  the  light  blinks,  followed  by  an  acoustic  

signal, the temperature ranges about 15°C  because of a default. The control board has to be checked. 

 

 

9. Maintenance 

Following the safety directions mentioned below is essential to avoid severe injuries to the operator and / or 

damage to the transfer press.  

Before performing any maintenance work, the transfer press must have been switched off and the plug 

must have been removed from the power socket.  

Note the high temperatures of the heating plate (top). It can take up to 15 minutes until the plate has cooled 

down to a temperature below 50° C.  

Carefully follow the instructions mentioned in this manual before performing any maintenance or cleaning work 

on the transfer press.  

Maintenance work must only be performed by skilled and specially trained staff.  

Before  switching  on  the  unit  again  after  maintenance  or  cleaning  work,  ensure  that  no  tools  or  spare  parts 

have been left in or on the unit and that shrouds, safety appliances, graphic symbols and instructions attached 

to the press are in good condition and easy to read.  

 

Summary of Contents for TS DUE

Page 1: ...ual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 OPERATING INSTRUCTIONS FOR PNEUMATIC Heat Transfer Press TS DUE with interchangeabl...

Page 2: ...sure that all operators of the transfer press have understood all instructions and graphic symbols labelled on the press Accidents can also be avoided by strictly following the safety regulations acc...

Page 3: ...The reclaim of defective parts after their replacement is at the discretion of Siser Parts needing to be replaced because of maintenance wear or carelessness are not included in this warranty Any clai...

Page 4: ...cable between heating plate and instrument box Now untighten the clamping element of the heating plate suspension remove the heating plate with care and put it down on a safe even surface Fit the bent...

Page 5: ...just underneath the supporting plates Now you can swap the present supporting plate for a plate of your choice and fix the new plate by tightening the fixing screws It is not necessary to swap the he...

Page 6: ...This manual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 TS DUE with plates cm 15x38 TS DUE with cap set...

Page 7: ...d to touch the lower supporting plates when closing the press or printing the textile as these operations involve a risk of getting squashed and burned It is strongly recommended that only one person...

Page 8: ...wer circuit The characteristic values of the power supply system must comply with the characteristics of the heat transfer press Please check the values stated on the label The coloured conductor mark...

Page 9: ...nto its original position 8 Adjust the real printing pressure by turning the pressure controller on the right upper side of the press To adjust the pressure turn it clockwise to increase the pressure...

Page 10: ...or use as soon as the desired temperature is reached It is always possible to check time and temperature by tapping the S button Working programms With the new control board TS2 3P 4 different program...

Page 11: ...with the control board If 000 appears on the display and the light blinks followed by an acoustic signal the temperature ranges about 15 C because of a default The control board has to be checked 9 M...

Page 12: ...dustrial unit All applicable laws concerning the disposal of industrial machinery in the country of the user must be followed Disconnect the unit from the power supply and dismantle it Sort the parts...

Page 13: ...cable run 15 supporting plate support 16 ferrule 17 speed controller on request 18 heating plate 19 teflon rod 20 heating rods 5 pcs 475 x 45 mm W 400 V 220 21 temperature sensor 1m long 22 teflon cov...

Page 14: ...nual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 12 Exploded View Exploded view of transfer press with order numbers 13 Electronic...

Page 15: ...This manual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015...

Page 16: ...This manual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 14 Electronic Diagram board S2...

Page 17: ...SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 14 Pneumatic Diagram 1 filter controller 2 mini controller 3 electronic valve 4 control of air flow 5 end...

Reviews: