CDR PlusWire User Guide 

B1051067 Rev. A 

 

i

Contents 

1.

 

Overview ........................................................................................ 1

 

1.1.

 

Purpose ...................................................................................................................................... 1

 

1.2.

 

Indications for Use .................................................................................................................... 1

 

1.3.

 

System Description ................................................................................................................... 1

 

1.4.

 

PC Workstation Description ...................................................................................................... 1

 

2.

 

Installing the CDR PlusWire Sensor ........................................ 3

 

2.1.

 

What You Will Need to Complete this Section ........................................................................ 3

 

2.2.

 

Connecting the CDR PlusWire Sensor ...................................................................................... 4

 

2.3.

 

Sensor Calibration File Installation ........................................................................................... 4

 

2.4.

 

Using the CDR PlusWire Sensor with CDR DICOM ............................................................... 5

 

2.5.

 

Acquiring X-ray Images with the Footpedal ............................................................................. 7

 

2.6.

 

Acquiring X-ray Images with Keyboard Shortcuts ................................................................... 7

 

2.7.

 

Disconnecting the CDR PlusWire Sensor ................................................................................. 7

 

3.

 

Replacing the CDR PlusWire Cable ......................................... 8

 

3.1.

 

What You Will Need to Complete this Section ........................................................................ 8

 

3.2.

 

Before Replacing the CDR PlusWire Cable .............................................................................. 9

 

3.3.

 

Description of the CDR PlusWire Utility................................................................................ 10

 

3.4.

 

After Replacing the CDR PlusWire Cable .............................................................................. 10

 

3.5.

 

CDR PlusWire Cable Replacement ......................................................................................... 11

 

4.

 

Protective Measures .................................................................. 15

 

4.1.

 

Cleaning and Disinfecting ....................................................................................................... 15

 

4.2.

 

Recommended Disinfectant .................................................................................................... 16

 

5.

 

Maintenance ................................................................................ 17

 

5.1.

 

Visual Inspection ..................................................................................................................... 17

 

5.2.

 

Periodic Maintenance .............................................................................................................. 17

 

5.3.

 

Damaged or Non-Functioning Sensor ..................................................................................... 17

 

Appendix A.

 

Reference ................................................................. 18

 

A-1.

 

Summary of Specifications ..................................................................................................... 18

 

A-2.

 

Leakage Current Statement ..................................................................................................... 18

 

A-3.

 

EMC Tables ............................................................................................................................ 19

 

 

Summary of Contents for Schick CDR PlusWire

Page 1: ...e User Guide B1051067 Sirona Dental Inc 30 30 47th Avenue Long Island City NY 11101 USA 718 937 5765 718 937 5962 fax Sirona Dental GmbH Sirona Stra e 1 5071 Wals bei Salzburg Austria PART NUMBER B105...

Page 2: ...oth US 5 912 942 US 5 841 126 US 6 456 326 US 6 549 235 US 6 570 617 US 6 744 068 US 7 369 166 CDR Wireless Sensors US 5 514 873 US 6 924 486 US 6 972 411 US 7 072 443 US 7 171 181 US 7 193 219 US D49...

Page 3: ...y Images with Keyboard Shortcuts 7 2 7 Disconnecting the CDR PlusWire Sensor 7 3 Replacing the CDR PlusWire Cable 8 3 1 What You Will Need to Complete this Section 8 3 2 Before Replacing the CDR PlusW...

Page 4: ...Compatible CDR Interfaces 9 Table 4 Specifications 18 Table 5 Guidance and Manufacturer s Declaration Electromagnetic Emissions 19 Table 6 Guidance and Manufacturer s Declaration Electromagnetic Immun...

Page 5: ...e each usage check the outer surface of the CDR PlusWire Sensor for any signs of physical damage or defect The surface of the CDR PlusWire Sensor should have a smooth finish with no evidence of chippi...

Page 6: ...sitioning System User Guide is distributed with Sensor Holder kits and is also available on our website www schickbysirona com Do Not Touch Exposed Connectors on Non Medical Equipment and the Patient...

Page 7: ...ent for purposes that correspond to its intended design and application only dentists or their designees are authorized to operate the system Installers to Ensure that CDR PlusWire Operates Optimally...

Page 8: ...e ESD particularly when the device is used in or around carpeted areas or low humidity environments During cable replacement when Sensor contacts are exposed it is especially important to protect the...

Page 9: ...Devices Directive MDD 93 42 EEC Indicates that in the European Union at the end of product life this device must be disposed of in accordance with the requirements of the Waste Electrical and Electron...

Page 10: ...andard EN 50419 and in accordance with WEEE Directive 2002 96 EC This crossed out wheeled bin symbol on the product or on its packaging indicates that this product must not be disposed of with other u...

Page 11: ...to specify that the equipment was put on the market after August 13 2005 Information for Reuse Centers Treatment and Recycling Facilities After August 13 2005 and as required by the WEEE Directive Si...

Page 12: ...B1051067 Rev A CDR PlusWire User Guide x CDR PlusWire CDR PlusWire Expanded View CDR PlusWire Completed Installation...

Page 13: ...in the case of SDX its USB interface are connected by appropriate USB cable to a compatible PC workstation 1 running Windows Vista or Windows XP When CDR PlusWire cables are replaced a utility is use...

Page 14: ...maging For optimum performance we recommend the following 1 Compatible operating system Windows Vista Windows XP 2 Intel Pentium D or Intel Core 2 Duo processors 3 2 GB RAM 4 Minimum 250 GB hard drive...

Page 15: ...llowing items shown below 1 CDR PlusWire Sensor and Cable 2 Mini CD containing the Sensor Calibration File 3 Sensor holster sheaths and these instructions 4 CD PlusWire Utility CD You will not need th...

Page 16: ...workstation To install the calibration file perform the following 1 Ensure that the physical connection between the CDR PlusWire Sensor and the CDR Remote or CDR Remote HS or the SDX Sensor interface...

Page 17: ...log box Re usable customized series can be created at the Series New Intraoral Series menu C The numbers in the text boxes correspond to how many target frames view boxes are included in this series Y...

Page 18: ...e system is ready to acquire an X ray image A Please Wait message may appear momentarily STEP 7 A In AutoTake mode activate the X ray source The message Reading Image from Sensor appears momentarily B...

Page 19: ...though the use of shortcut keys Refer to the following table for keyboard shortcuts available to navigate patient exams and to acquire images in CDR Table 2 Keyboard Shortcuts Desired Action Use Keys...

Page 20: ...1205101 6 ft cable B1205103 9 ft cable Each Cable Replacement Kit includes the following items 1 CDR PlusWire cable assembly 3 6 or 9 foot lengths 2 CD containing the CDR PlusWire Utility 3 Phillips f...

Page 21: ...oraround carpeted areasorlow humidityenvironments Duringcablereplacement whenSensorcontactsare exposed it isespeciallyimportanttoprotectthedevicefrompotentialESDdamage Touchingametalsurfacepriorto rep...

Page 22: ...om one edge card connector and write it to the new edge card connector To accomplish this the utility consists of a few dialog boxes that will prompt you through the entire process Refer to Section 3...

Page 23: ...or Sensor Interface on the SDX Intraoral X ray System 2 A Insert the CDR PlusWire Utility CD at the workstation where the cable is connected B Browse to your CD drive and double click on CDR PlusWire...

Page 24: ...iginal cable to be replaced from the CDR Interface 9 Connect the new replacement cable to the CDR Interface You do not need to have the cable attached to the Sensor for this step 10 Verify that the Wr...

Page 25: ...or 14 Carefully peel away the black label from the back of the Sensor 15 A Using the small screwdriver provided remove the 4 screws and the old cable B Remove the old elastomeric strip from the Sensor...

Page 26: ...sor mates with the corresponding keying feature in the cable assembly 18 Attach the replacement cable to the Sensor using 4 screws provided Tighten screws securely but do not apply excessive force 19...

Page 27: ...a patient or otherwise they should be cleaned following the same protocol as the CDR PlusWire Sensor Sensor positioning accessories such as aiming rings arms and holders should be cleaned and disinfe...

Page 28: ...infecting products recommended in Section 4 2 on page 16 Do not expose the Sensor cable connectors to any amount of liquid 8 If using a spray disinfectant allow it to remain on the Sensor for 5 minute...

Page 29: ...erformed by the operator or by a qualified service technician Check that the labels are intact readable and adhere well to the surfaces on which they are positioned Check that all of the cables are un...

Page 30: ...of a Flammable Anesthetic Mixture with Air or with Oxygen or Nitrous Oxide Supply Voltage 5V DC derived for PC USB port Supply Current 250 mA Power Consumption 1 25W Outer Sensor mm 37 x 24 size 1 43...

Page 31: ...sions IEC 61000 3 3 Complies Table 6 Guidance and Manufacturer s Declaration Electromagnetic Immunity PLEASE NOTE CDR PlusWire is intended for use in the electromagnetic environment specified below Th...

Page 32: ...Vrms 150 kHz to 80 MHz 3 Vrms Portable and mobile RF communication equipment should be used no closer to any part of CDR PlusWire including its cables than the recommended separation distance calcula...

Page 33: ...and Mobile RF Communications Equipment and CDR PlusWire PLEASE NOTE CDR PlusWire is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or...

Page 34: ...rrent Statement 18 M Maintenance 17 O Operate CDR PlusWire Sensors as Directed iii Overview 1 P Periodic Maintenance 17 Proper System and PC Workstation Installation and Operation v Protective Measure...

Page 35: ...CDR PlusWire User Guide B1051067 Rev A 23 V Visual Inspection 17 W Waste Electrical and Electronic Equipment WEEE viii Workstation 1...

Reviews: