Installation guide
FM 0120 E 1
26/07/10
Ind.
B
SIROCO S.A.S.
10 rue Jean Rostand - Z.I.
BP 135
69745 GENAS Cedex
Tel: +33 (0)4 78 90 96 96
Fax: +33 (0)4 78 90 15 98
www.siroco.fr
Page 4 of 6
Fix product on its cut stand with 8 not supplied screws. Blower motor axis should rather be
in horizontal position on the vehicle.
Do not drill heater’s body so as not to damage heat exchanger !
Connect water input and output by using cooling pipes with corresponding diameter. Using
suitable clamping rings.
Check for leaks in water.
Fixation stand
2
3
235 x 170 mm
cut-out
8 not supplied
screws
8 Ø 3,7 mm
Clamping
rings
Inlet pipe
3
3
Outlet pipe