SIROCO ARIZONA Installation Manual Download Page 2

 

Installation guide

 

FM 0120 E 1 

26/07/10 

Ind. 

 

 

 

 

SIROCO S.A.S. 
10 rue Jean Rostand - Z.I. 
BP 135 
69745 GENAS Cedex 

Tel: +33 (0)4 78 90 96 96 

Fax: +33 (0)4 78 90 15 98 

www.siroco.fr 

Page 2 of 6 

 

1 - Device description 

 
ARIZONA heater consist of a blower, a coil, a plastic part and a removable front plate. Plastic part is 
made  from  polypropylene.  Front  plate  is  made  from  heat  and  impact  resistant  ABS.  Heater  can 
operate under three different speeds: a control knob enables to select speed from front plate. There 
are two input air supply (on heater side), an output air supply (on front plate) and an input-output 
cooling water supply. Heater including an integrated valve controlled from front plate with a knob. 
 
ARIZONA’s front plate is available in different  colors : white, grey, anthracite or black.  Heater can 
be  equipped  with  600,  400  or  300  blower  that  supplied  in  12  V  or  24  V  with  connections  pipes 
diameters of 16 mm. 
 
 

 

 
 
 

 

 

 

 

 

 

 

 

      

 
 
 
 
 
 
 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Product part numbers:

 

  

 

ARIZONA 600 

ARIZONA 400 

ARIZONA 300 

Voltage 

Front plate 

color 

Part number 

Part number 

Part number 

White 

0120 0001 

0120 0101 

0120 0201 

Grey 

0120 0002 

0120 0102 

0120 0202 

Anthracite 

0120 0003 

0120 0103 

0120 0203 

12 V 

Black 

0120 0004 

0120 0104 

0120 0204 

White 

0120 0005 

0120 0105 

0120 0205 

Grey 

0120 0006 

0120 0106 

0120 0206 

Anthracite 

0120 0007 

0120 0107 

0120 0207 

24 V 

Black 

0120 0008 

0120 0108 

0120 0208 

Blower 

Air outlet 

Heat exchanger 

Water output 

Polypropylene

 

plastic part 

Electrical wires 
(cross-section 1,5 mm

2

 

Valve control knob 

 

Valve 

3 speeds control knob 

Water input 

Double poles 
connector 

ABS front plate 
(supplied sectional) 

  

Knobs location 

Summary of Contents for ARIZONA

Page 1: ... Ind B Page 1 of 6 ARIZONA 1 Device description 2 Operation 3 Mounting information 4 Trouble shooting 5 Security advice SIROCO S A S 10 rue Jean Rostand Z I BP 315 69745 GENAS Cedex Tel 33 0 4 78 90 96 96 Fax 33 0 4 78 90 15 98 www siroco fr ...

Page 2: ...knob ARIZONA s front plate is available in different colors white grey anthracite or black Heater can be equipped with 600 400 or 300 blower that supplied in 12 V or 24 V with connections pipes diameters of 16 mm Product part numbers ARIZONA 600 ARIZONA 400 ARIZONA 300 Voltage Front plate color Part number Part number Part number White 0120 0001 0120 0101 0120 0201 Grey 0120 0002 0120 0102 0120 02...

Page 3: ...d anticorrosive for copper and aluminum Use a cooling fluid officially recognize by automotive manufacturers Technical data Type Voltage Electrical power Weight Nominal air flow Heating capacity L depth see 3 step 2 ARIZONA 600 12 24 V 150 W 2 3 kg 380 m h 6 10 kW 227 mm ARIZONA 400 12 24 V 120 W 2 kg 285 m h 5 00 kW 218 mm ARIZONA 300 12 24 V 55 W 2 kg 200 m h 4 35 kW 218 mm Optimum heating capac...

Page 4: ...ith 8 not supplied screws Blower motor axis should rather be in horizontal position on the vehicle Do not drill heater s body so as not to damage heat exchanger Connect water input and output by using cooling pipes with corresponding diameter Using suitable clamping rings Check for leaks in water Fixation stand 2 3 235 x 170 mm cut out 8 not supplied screws 8 Ø 3 7 mm Clamping rings Inlet pipe 3 3...

Page 5: ... Replace cable Check for correct cable routing and connections according to the circuit diagram Electrical connections reversed Check connecting wires according to the circuit diagram and if necessary assemble correctly Blower switch defective Replace the switch with a new original component Blockage in fan unit Rectify cause of blockage e g object in impeller If necessary order new unit Blower no...

Page 6: ... to the maximum Water flow rate through heat exchanger is too low Water lines kinked or squashed Relay hoses Water pump pressure too low see above for action Flush out water circuit Air in heat exchanger When the pumping pressure is sufficient the heater is self bleeding Install additional or more powerful water pump Unit is underdimensioned Install a more powerful unit Insufficient pumped water p...

Reviews: